Program
Program
Code Function
Code
Description
Entry
Code
26
Issue/Rev.
03
(8/97)
200
System Flow Control Directory 200
201
Low Flow Start Volume Enter: Four digits in whole
201
units (e.g., 0100)
__ __ __ __
Note: The larger of the volumes as programmed in this code or calculated in code 202 will be used as the low flow start volume.
202
Low Flow Start
Enter:
Two digits in whole percentage
202
Percentage
indicating the percentage of the preset
to be delivered during low flow start
(e.g., 10%)
__ __
Note: The larger of the volumes as calculated using the percentage entered in this code or the volume entered in code 201 will be used as the low
flow start volume.
203
Low Flow Start Rate
Enter:
Four digits in whole
203
units per minute (e.g., 0150)
"0000" entry will not allow
the valve to open.
__ __ __ __
204
Low Flow Start
Enter:
"0" Low Flow Start always after
204
zero flow.
"1" Low Flow Start at beginning
of batch only.
___
205
System First High
Enter:
Four digits in whole units
205
Flow Rate
(e.g., 0600) "0000" Entry will not
allow the valve to open.
__ __ __ __
206
System Second High
Enter:
Four digits in whole units
206
Flow Rate
(e.g., 0300) "0000" Entry will not
allow the valve to open if configured
for 1st/2nd High Flow.
__ __ __ __
207
Overrun Alarm Limit
Enter:
Two digits in whole
207
units (e.g., 15)
"00" disables the alarm
__ __
208
Zero Flow Timer
Enter:
Two digits in seconds (e.g., 15)
208
"00" disables this option
__ __