A

Assembly

CABLES - IMPORTANT
If you want to use an extension cable when operating
your product, only the following cable dimensions
should be used:
- 1.0 mm

2

: max length 40 m

- 1.5 mm

2

: max length 60 m

- 2.5 mm

2

: max length 100 m

Minimum rating :
1.00mm

2  

size cable, 10 amps 250 volts AC.

• YOUR PRODUCT IS SUPPLIED WITH CABLE

WIRED DIRECTLY INTO THE PRODUCT.

1. If the supply cord is damaged, it must be replaced

by your local Husqvarna UK Ltd. Approved Service
Centre or similarly qualified persons in order to avoid
a hazard.

2.Flymo Extension Cables are available from your 

local Husqvarna UK Ltd. Approved Service Centre. 

3.Do not wire an extension cable directly to your product

yourself.  Please contact your local Husqvarna UK Ltd.
Approved Service Centre for further information on the
connectors and kits available.

4.Only use extension cables specifically designed for

outdoor use and which conform to one of the following
specifications: Ordinary rubber (60245 IEC 53), Ordi-
nary PVC (60227 IEC 53) or Ordinary PCP (60245
IEC 57)

CONNECTORS - IMPORTANT
• Flymo connectors are suitable for use with 2 core

cable only.  Under no circumstances should these
connectors be used for earthed products.

• All Flymo connectors and cables are of splashproof

construction.  They are not waterproof and must not

be left outside permanently nor should they be sub-
merged or immersed in water.  Do not let cable lay or
trail through pools of water or splashed with water
from hose pipes.

MAINS PLUG REPLACEMENT - IMPORTANT
• If the plug supplied is cut off it should be destroyed.

There is an electric shock hazard if a cut off plug is in-
serted into a 13 amp socket.

1.No earth required. Flymo products are double insu-

lated to EN60335  and under no circumstances
should an earth be connected to any part of the prod-
uct.

2. Ensure the mains voltage suits your product
3. IMPORTANT!

The wires in the mains lead are coloured in accor-
dance with the following code:
BLUE        -     NEUTRAL
BROWN    -     LIVE
The wire which is coloured BLUE must be connected
to the Terminal which is marked with the letter 'N' or
coloured BLACK.  
The wire which is coloured BROWN must be con-
nected to the Terminal which is marked with the letter
'L' or coloured RED. 

4.It is important that the outer sheath is clamped cor-

rectly into the 3-pin plug. 

5.If in doubt consult your local Service Repairer or quali-

fied electrician before the machine is used.  

6.A 13 Amp fuse must be fitted to the Mains Plug. 
7.The normal plug fuse and household fuse only protect

the electrical equipment and are not a safeguard
against electrocution.

Preparing your lawnmower for use

Your lawnmower is supplied with the upper handle
folded over the machine for packing and transporta-
tion.

Handle in Operating Position
1. Lift handle as illustrated in figure A.

Do not drop the handle.

Make sure that the cable does not become trapped
between the handles

To Start your Lawnmower
1. Connect plug to mains and switch on.
The switchbox is provided with a lock-off button (B1) to
prevent accidental starting.
2. Press and hold the lock-off button (B1) on the switch-

box, then squeeze one of the Start/Stop levers towards
the upper handle (C).

3. Continue to squeeze the start/stop lever towards the

upper handle and release the lock-off button.(D)

NOTE: There are two start/stop levers fitted. Either one
can be used for starting the lawnmower.  IMPORTANT:
Do not use the start/stop levers intermittently.

To Stop your Lawnmower
1. Release the pressure on the Start/Stop lever.

Starting and Stopping

B

D

1

C

1

Cables

Содержание EASI GLIDE 300

Страница 1: ...IMPORTANT INFORMATION Read before use retain for future reference Original Instructions EASI GLIDE 300 EASI GLIDE 300V EASI GLIDE 330 EASI GLIDE 330VX...

Страница 2: ...lowing the warning and safety in structions in this manual and on the lawnmower Never use the lawnmower unless the grassbox or guards provided by the manufacturer are in the correct position Explanati...

Страница 3: ...ted to EN60335 Under no circumstance should an earth be con nected to any part of the product Preparation 1 While using your product always wear substantial footwear and long trousers Do not operate w...

Страница 4: ...d Flymo products are double insu lated to EN60335 and under no circumstances should an earth be connected to any part of the prod uct 2 Ensure the mains voltage suits your product 3 IMPORTANT The wire...

Страница 5: ...tating BEFORE lifting the grassbox lid 1 Lift the grassbox lid and rest it against the motor cover J 2 Remove the grassbox using the moulded handle re cesses at the front and rear of the grassbox K 3...

Страница 6: ...that the blade is positioned as illustrated in Figure M 4 Place the blade bolt M1 through the centre hole of the blade 5 Tighten down clockwise by hand 6 Hold the fan firmly and tighten the blade bol...

Страница 7: ...s and openings are not obstructed 5 Raise to a higher height of cut See Adjusting the Cutting Height 6 If poor collection persists Disconnect from the mains electricity supply and consult your local a...

Страница 8: ...rranty claim Blades Belt Electric Mains cable Caution Husqvarna UK Ltd does not accept liability under the warranty for defects caused in whole or part di rectly or indirectly by the fitting of replac...

Страница 9: ...aximum A weighted sound pressure level LpA at the operator s position measured according to EN60335 2 77 corresponds to the Level given in the table The maximum hand arm vibration weighted value measu...

Отзывы: