27
VIBRONET Installation 06.2016
Installation
Connecting RPM sensor and temperature probe
To connect these sensors to the Multiplexer you need special connec-
tion modules that are available as an accessory:
-
RPM module: VIB 8.313,
-
Temperature module: VIB 8.310
Connect the module to the MUX as follows:
• Open the MUX housing.
NOTE
Observe the ESD protection regulations
Electrostatic discharges can damage circuit paths and components.
• Do not touch the board.
• Remove the cable shield contact from the MUX circuit board.
• Insert the signal pin of the module into the corresponding connec-
tion contact (but do not tighten it down yet).
• Screw the module firmly onto the circuit board.
• Tighten down the connection contact.
Connect the sensor cable to the connection module as follows:
• Open a suitable MUX fitting.
• Insert the sensor cable into the MUX.
• Connect the sensor cable to the module.
• Tighten down the MUX fitting.
Cable shield contact
Signal pin
2-4
5
Cable shield
contact removed
Signal contact
Connecting the module to the
MUX
Connecting the sensor cable to
the module