Fluke U1500s Скачать руководство пользователя страница 2

• Examine the case before you use the Product. Look for 

cracks or missing plastic. Carefully look at the insulation 

around the terminals.

• Do not use the Product around explosive gas, vapor, or in 

damp or wet environments.

• Use Product-approved measurement category (CAT), 

voltage, and amperage rated accessories (probes, test 

leads, and adapters) for all measurements.

• Do not use test leads if they are damaged. Examine the 

test leads for damaged insulation and measure a known 

voltage.

• Do not use the Product if it is damaged.
• Do not use the Product if it operates incorrectly.
• The battery door must be closed and locked before you 

operate the Product.

• Remove all probes, test leads, and accessories before the 

battery door is opened.

• Do not work alone.
• Do not exceed the Measurement Category (CAT) rating of 

the lowest rated individual component of a Product, 

probe, or accessory.

• Do not touch voltages >30 V ac rms, 42 V ac peak, or 

60 V dc.

• Do not apply more than the rated voltage, between the 

terminals or between each terminal and earth ground.

• Measure a known voltage first to make sure that the 

Product operates correctly.

• Disable the Product if it is damaged.
• Use only specified replacement parts.
• Have an approved technician repair the Product.

Table 

1

 shows the symbols that can be used on the Product or in this 

manual. 

Table 1. Symbols

Symbol

Definition

W

WARNING - RISK OF DANGER.

X

WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.

Consult user documentation.

Earth

T

Double Insulated

Alkaline

Battery

P

Conforms to European Union directives.

)

Certified by CSA Group to North American safety standards.

Содержание U1500s

Страница 1: ...ngapore 65 6799 5566 Anywhere in the world 1 425 446 5500 Customer Service Center Fluke China 400 810 3435 Maintenance Service Center Fluke China 400 921 0835 To view print or download the latest manu...

Страница 2: ...the battery door is opened Do not work alone Do not exceed the Measurement Category CAT rating of the lowest rated individual component of a Product probe or accessory Do not touch voltages 30 V ac rm...

Страница 3: ...off the Product after test completion then unplug the test leads Conforms to relevant Australian Safety and EMC standards Conforms to relevant South Korean EMC Standards Measurement Category III is ap...

Страница 4: ...Disconnect all Probe connections 2 Make sure that the power switch is OFF 3 Use a flat blade screwdriver to rotate the battery door fastener to the unlocked position 4 Remove the battery door 5 Insta...

Страница 5: ...Have an approved technician repair the Product If the Product does not perform properly use these steps to help isolate the problem 1 Verify that battery capacity meets the requirements 2 Verify that...

Страница 6: ...V DC 1500 V Electromagnetic Compatibility EMC International IEC 61326 1 Portable Electromagnetic Environment IEC 61326 2 2 CISPR 11 Group 1 Class A Group 1 Equipment has intentionally generated and or...

Страница 7: ...R 15 subpart B This product is considered an exempt device per clause 15 103 Electrical Specifications Measurement Range 1000 V ac rms 1500 V dc Accuracy 0 1 of reading 0 1 of Range Bandwidth 100 kHz...

Страница 8: ...on then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIE...

Отзывы: