background image

 

IR InSight Thermal Imager 

 

Connecting the Camera to a Computer   

  

19 

5.

 

Return to the main menu by pulling and holding the Frame Capture 
Trigger for 3 seconds.  

6.

 

Return to Scan Target mode by highlighting “Run Normally” from 
the main menu, then releasing the Frame Capture Trigger for 4 
seconds. 

Saving and Naming an Image  

Whenever an image is saved, the image ID number is increased progressively 
from 1 to 255. The image file name, when first saved, consists of a four 
character year, a two character month, a two character day, a week day, a two 
character hour, a two character minute, a two character second, and a three 
digit image ID number. 

You can rename the file using SmartView installed on a personal computer. 
However, the original time and date stamp imbedded in the image file remains 
unchanged. 

Connecting the Camera to a Computer 

You can connect your Camera to a personal computer (PC) installed with 
SmartView™ software and transfer images saved in the Camera’s memory to 
the PC. Then, use SmartView to add annotations, references, and comments to 
your InSight images, as well as change image color palettes and rename, 
analyze, organize, and print images. 

Note 

 If the PC you are using has both RS-232 and USB options, connect 
the Camera to the PC using the RS-232 port and cable. If the PC has 
only a USB port, use a combination of the RS-232/USB cable and  
RS-232 cable. The procedures for both options are described on the 
following pages.  

Using an RS-232 Port Connection 

To connect the Camera to a PC using the PC RS-232 port: 

1.

 

Connect the RS-232 cable to the PC and Camera. 

2.

 

Be sure SmartView is installed on your PC then open the application. 

Содержание InSight XS Series

Страница 1: ...XS XST IR InSight Thermal Imager Users Manual May 2006 Rev 1 8 06 2006 Fluke Corporation All rights reserved All product names are trademarks of their respective companies...

Страница 2: ...e center to obtain return authorization information then send the product to that service center with a de scription of the difficulty postage and insurance prepaid FOB Destination Fluke as sumes no r...

Страница 3: ...he Internal Calibration Function 14 Focusing 14 Changing Color Palettes 15 Changing Date and Time 15 Using External Video Output Devices 16 Obtaining the Center Point Temperature 16 Setting Emissivity...

Страница 4: ...XS XST Users Manual ii Inserting and Removing the Battery 25 Camera Care 26 Appendices A Emissivity Values A 1 B Camera Specifications and Dimensions B 1 Index...

Страница 5: ...trols Camera Back 11 4 Display Screen Features and Controls Scan Target Mode 12 5 Display Screen Features and Controls Review Image Mode 13 6 Lens Field of View and Instantaneous Field of View 24 7 Ba...

Страница 6: ...XS XST Users Manual iv...

Страница 7: ...d Off 6 5 Selecting Palette Color 7 6 Focusing the Camera 7 7 Features and Controls Camera Front 9 8 Features and Controls Camera Back 10 9 Display Screen Features and Controls Scan Target Mode 11 10...

Страница 8: ...XS XST Users Manual vi...

Страница 9: ...Using the SmartView companion PC software application you can examine analyze enhance and archive your images and data Your Camera provides high performance thermal imaging and is designed for buildin...

Страница 10: ...lections from these devices may adversely affect Camera accuracy and may harm or permanently damage your Camera s IR detector Your Camera was calibrated prior to shipping We recommend that you have yo...

Страница 11: ...ning the shipping box Be sure to save the box and shipping materials in case you need to ship the Camera Inside the shipping box you will find a hard carrying case containing the standard accessories...

Страница 12: ...r D XS XST Getting Started Guide Charge and Insert Battery Note The battery fits into the charger and the Camera only one way Charge a new battery as shown in Figure 2 for 24 hours thereafter a comple...

Страница 13: ...IR InSight Thermal Imager Charge and Insert Battery 5 eiw002 eps Figure 2 Charging the Battery eiw003 eps Figure 3 Inserting the Charged Battery...

Страница 14: ...Camera On and Off Note After powering on the Camera it requires a boot up and warm up period of approximately 30 seconds in order to maintain a crisp clear real time image About five minutes after pow...

Страница 15: ...alette you want as shown in Figure 5 See Changing Color Palettes in later in this manual for additional palette options eiw005 eps Figure 5 Selecting Palette Color Focus Remove the lens cap point the...

Страница 16: ...ed image on the display screen for further review do not release the Frame Capture Trigger when capturing the image The Camera automatically returns to the Scan Target mode once you release the Frame...

Страница 17: ...B RS 232 Port Used to connect camera to a computer for downloading or deleting images C Frame Capture Trigger Used to pause and save an image frame and to advance through saved images or menu items D...

Страница 18: ...D Screen B Camera Lanyard Bracket C ON OFF Switch Used to power camera on and off and to select desired color palette option Display screen features and controls for scan target mode are shown in Figu...

Страница 19: ...shades from coldest to hottest temperature C Center Point Includes the center 2 X 2 pixels XST model only D Date Displays the current month day and year E Time Displays the current time 24 hour clock...

Страница 20: ...re Trigger to access and navigate through display screen menus To access the main menu start the Camera while simultaneously pulling and holding the Frame Capture Trigger From the main menu pull and r...

Страница 21: ...Transfer thermographic images to a computer and efficiently manage them Optimize and analyze your infrared and visible light control images Create and print detailed professional reports containing i...

Страница 22: ...rt up toggle the ON OFF switch to the right while simultaneously pulling and holding the Frame Capture Trigger To power the camera off toggle the ON OFF switch to the left Understanding the Internal C...

Страница 23: ...ette change and return to the main menu Maintain the Frame Capture Trigger release for another 4 seconds to return to Scan Target mode or go to Step 5 to change the second selected palette 5 To change...

Страница 24: ...8 F Many common target materials such as painted surfaces human skin water electrical wire insulation wood and most types of tape have an emissivity value of approximately 0 95 See Appendix A for the...

Страница 25: ...download the images following the procedure under Downloading Images to a Computer found later in this Manual Then in SmartView highlight the desired image click on the emissivity value or background...

Страница 26: ...Trigger Review Images To view images saved to the Camera s internal memory Note Review Images mode must be started from the main menu If there are no saved images Review Images does not appear in the...

Страница 27: ...original time and date stamp imbedded in the image file remains unchanged Connecting the Camera to a Computer You can connect your Camera to a personal computer PC installed with SmartView software an...

Страница 28: ...n the sign next to the word Ports The actual port number may depend on the devices currently in use on the PC When prompted to use these settings in future sessions select Yes 4 Toggle the ON OFF swit...

Страница 29: ...ch communications port to select access the PC device manager on the PC desktop Right click on the My Computer icon and select Properties Go to the Hardware tab and select Device Manager A Device Mana...

Страница 30: ...for Folder pop up window choose the folder in which you want to store the images 5 Click OK to start the download process A pop up window appears indicating the number of images being downloaded As t...

Страница 31: ...menu pull and release the Frame Capture Trigger to highlight Erase All Images and then release the Frame Capture Trigger for 4 seconds 3 Are You Sure appears Highlight Yes and release the Frame Captu...

Страница 32: ...rformance and life charge a new battery for 24 hours the first time Thereafter a completely discharged battery takes approximately 30 minutes to charge 1 Connect the battery charger AC power supply to...

Страница 33: ...mperature drops Orange Flashing Charging not possible Battery and or charger terminals may be dirty or the battery pack is malfunctioning Inserting and Removing the Battery To insert the battery align...

Страница 34: ...amera in the case when you are not using it WCaution To avoid damaging your camera use compressed air to remove large particles and dust prior to using a cloth To clean the lens Lightly rub the lens w...

Страница 35: ...Appendices Appendix Title Page Emissivity Values A 1 Camera Specifications and Dimensions B 1...

Страница 36: ...XS XST Users Manual...

Страница 37: ...ls Material Temperature C Emissivity Aluminum polished 0 0 05 Aluminum rough surface 0 0 07 Aluminum strongly oxidized 0 0 25 Asbestos board 0 0 96 Asbestos fabric 0 0 78 Asbestos paper 0 0 94 Asbesto...

Страница 38: ...powdered 0 0 96 Chromium polished 0 0 10 Clay fired 0 0 91 Concrete 0 0 54 Copper polished annealed 0 17 0 01 0 02 Copper commercial burnished 0 0 07 Copper oxidized 0 0 65 Copper oxidized to black 0...

Страница 39: ...28 Lacquer Bakelite 0 0 93 Lacquer black dull 0 0 97 Lacquer black shiny 0 0 87 Lacquer white 0 0 87 Lampblack 0 0 96 Lead gray 0 0 28 Lead oxidized 0 0 63 Lead red powdered 0 0 93 Lead shiny 0 0 08...

Страница 40: ...hellac black dull 0 0 91 Shellac black shiny 0 0 82 Snow 0 0 80 Steel galvanized 0 0 28 Steel oxidized strongly 0 0 88 Steel rolled freshly 0 0 24 Steel rough surface 0 0 96 Steel rusty red 0 0 69 Ste...

Страница 41: ...0 by 120 Focal Plane Array Detector Size 51 m Square Spectral Band 8 m to 12 m Thermal Sensitivity 30 Hz 0 07 C at 30 C Video Frame Rate 30 Hz Display and Image Storage Digital Display 3 1 2 in LCD On...

Страница 42: ...0 95 and background temperature at 20 C 68 F on camera both can be changed on PC with analysis software SmartView provided with camera Optics Standard Lens Germanium 20 mm f 0 8 23 Horizontal x 17 Ver...

Страница 43: ...battery 1 86 kg 4 12 lbs Size 12 7 cm x 8 89 cm x 27 94 cm 5 in x 3 5 in x 11 in Environmental Operating Temperature 10 C to 50 C 14 F to 122 F Storage Temperature 40 C to 70 C 40 F to 158 F Humidity...

Страница 44: ...XS XST Users Manual B 4...

Страница 45: ...perature 16 charging batteries 24 cleaning camera body 26 display screen 26 lens 26 color palette changing 15 communication port configuring RS 232 19 configuring USB 20 computer connecting camera to...

Страница 46: ...mode 18 PC See personal computer personal computer connect camera 19 download images to 22 power camera off 14 on 14 R review image mode 18 reviewing images 17 RS 232 port 19 S safety information 2 s...