General Characteristics 

Head Cable  
Length  
(double insulated) 

610 mm (24 in.) i6000s Flex-24 
915mm (36 in.)  i6000s Flex-36 

Cable Diameter 

14.3 mm (0.562 in) 

Bend Radius 

38.1 mm (1.5 in) 

Cable Length 

2 m long (78.7 in) (head to electronics) 

Output  
Connection 

0.5 m cable terminated with safety BNC 
connector Supplied with 4 mm safety plug 
adapter 

Operating 
Temperature 

- 20 °C to +90 °C  (-4 to 194 °F) (head) 
- 20 °C to +85 °C  (-4 to 185 °F) (electronics) 

Storage 
Temperature 

- 40 °C to +105 °C (-40 to 221 °F) (head) 
- 20 °C to +85 °C (-4 to 185 °F) (electronics) 

Operating  
Humidity 

15 % to 85 % (non-condensing) 

Weight 

180 g (head), 190 g (electronics) 

Safety Standards 

EN 61010-1: 2001 
EN 61010-2-032: 2002 
EN 61010-031: 2002 
600 V rms Category III, Pollution Degree 2. 

Use of the Probes on 

uninsulated conductors

 is limited to 600 

V ac rms or dc and frequencies below 1 kHz. 

EMC Standards 

EN 61326 : 1998 +A1, A2, & A3 

Содержание i6000s Flex-24

Страница 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Страница 2: ...to the current being measured The Probes provide full scale direct readings for 60 A 600 A and 6000 A Symbols The following table shows the symbols used on the product and or in this manual Symbol Des...

Страница 3: ...uctors Always de energize the circuit under test before installing the flexible measuring head Always inspect the electronics unit connecting cable and flexible measuring head for damage before using...

Страница 4: ...reading Noise 8 mV ac rms 60 A 2 mV ac rms 600 6000 A Frequency Range 10 Hz to 50 kHz 3 dB Phase error 1 45 65 Hz 10 at 20 kHz Position sensitivity with cable 25 mm from the coupling 2 of range Exter...

Страница 5: ...ug adapter Operating Temperature 20 C to 90 C 4 to 194 F head 20 C to 85 C 4 to 185 F electronics Storage Temperature 40 C to 105 C 40 to 221 F head 20 C to 85 C 4 to 185 F electronics Operating Humid...

Страница 6: ...wf0001 eps A Measuring head B Measuring head coupling C Head output cable D Enclosure E Power on Range selector F Battery low indicator G Power on indicator H Output cable I Safety BNC connector J Ext...

Страница 7: ...move the battery cover 3 Install the batteries ensuring that correct polarity is observed 4 Replace the battery cover and turn the battery lock until the dot aligns with the lock symbol External Power...

Страница 8: ...m the nearby conductors WX Warning To avoid electric shock or injury Do not use the flexible current Probes to measure bare conductors unless wearing protective clothing suitable for high voltage work...

Страница 9: ...is Fluke product will be free from defects in material and workmanship for one year from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect mi...

Отзывы: