Specifications
Electrical Characteristics
Current Ranges
60 A / 600 A / 6000 A ac rms
Output Sensitivity
(AC Coupled)
50 mV / 5 mV / 0.5 mV per A
Load Impedance
100 k
Ω
minimum
Accuracy (at 25 ºC)
±
1% of range (45 – 65 Hz)
Linearity
(10 % to 100 % of range)
±
0.2 % of reading
Noise
8 mV ac rms (60 A)
2 mV ac rms (600/6000 A)
Frequency Range
10 Hz to 50 kHz (- 3 dB)
Phase error
<
±
1° (45 – 65 Hz),
±
10° (at 20 kHz)
Position sensitivity
(with cable > 25 mm from
the coupling)
±
2 % of range
External field
(with cable
>
200 mm
from the head)
±
1 % of range
Power Supply
2 x AA MN 1500 LR6 Alkaline
400 hours, low battery indicator
or dedicated ext power supply
Temperature Coefficient
±
0.08 % of reading per °C
Working Voltage
600 V ac rms or dc