Electrical Tester
Performance Tests
7
Testing the LEDs
Use the following procedure to test the LEDs:
Note
The Tester must remain inactive for approximately 30 seconds before
performing the following test. This will force a processor reset that will
display all LCD segments for approximately 1 second at power up.
1.
Short the test probes together.
2.
Observe that all LEDs light (voltage range, hazard, volts ac and dc, and continuity).
Testing the Backlight (T+ PRO)
Use the following procedure to test the backlight:
1.
Insert the test probes into a voltage source of > 10 V ac or dc.
2.
Observe that the backlight lights.
Testing the Audible Signal
Use the following procedure to test the audible signal:
1.
Short the UUT test probes together. The beeper should sound.
2.
If inactivated, press and hold
until you hear three beeps.
Testing the Flashlight
Use the following procedure to test the flashlight:
1.
Press the UUT headlight button.
2.
Observe that the flashlight turns on for approximately five seconds.
Содержание EW-26046-44