T+ and T+ PRO
Calibration Information
4
Specifications
Temperature Performance
Operating ...........................................................
−
10
°
C to 55
°
C (14
°
F to 131
°
F)
Storage ...............................................................
−
30
°
C to 60
°
C (
−
22
°
F to 140
°
F)
Relative Humidity
90 % .................................................................... 0
°
C to 30
°
C (32
°
F to 86
°
F)
75 % .................................................................... 30
°
C to 40
°
C (86
°
F to 104
°
F)
45 % .................................................................... 40
°
C to 50
°
C (104
°
F to 122
°
F)
Altitude
Operating ............................................................ 2,000 m
Storage ............................................................... 10,000 m
Battery Type/Life
................................................... AAA (2); 40 hours
Shock, Vibration
.................................................... Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument
Safety
..................................................................... ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010-1 to 1000 V CAT
III/600 V CAT IV
AC Bandwidth
.......................................................
45 Hz to 66 Hz
Earth Ground
.........................................................
MAXIMUM working voltage 1000 V ac or dc
MAXIMUM measurable voltage 600 V ac or dc
This will be displayed on the LED and LCD (T+ PRO)
Duty Cycle
..............................................................
Indefinitely for voltages up to 240 V.
For voltages between 240 V to 600 V, the duty cycle is 30 s on / 300 s
off. For voltages above 240 V, the Tester must connect to a voltage
source only for a MAXIMUM of 30 s and then disconnect for a
MINIMUM of 300 s.
Voltage Hazard LED
..............................................
LEDs turn on
@ voltages > 30 V ac/dc
±
35 %
LEDs
....................................................................... LEDs turn on @ between 70 % and 100 % of the indicated voltage on
the LED, except for the 12 V LED that turns on @ between 50 % and
100 %.
Accuracy
AC voltage ..........................................................
±
(3 % rdg + 2 digits)
DC voltage ..........................................................
±
(2 % rdg + 2 digits)
Resistance ..........................................................
±
(5 % rdg + 3 digits)
LCD Resolution ................................................... 0.1 V for voltages < 50 V, 1 V for voltages
≥
50 V, 0.01 k
Ω
at
resistance measurement
GFCI Test Current .............................................. 100 V to 150 V @ 6 mA to 9 mA ac
150 V to 240 V < 12 mA
Standard Input Test Current
................................ < 5 mA
Size (HxWxL) .........................................................
1.3 x 2.15 x 7.6 in.
Weight
.................................................................... 9.9 oz