Fluke etherscope II Скачать руководство пользователя страница 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service.  The warranty period for 
the mainframe is one year and begins on the date of purchase.  Parts, accessories, product repairs and services are warranted for 90 days

unless other-

wise stated.  Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories.  The warranty extends only to the 
original buyer or end user customer of a Fluke Networks authorized reseller, and does not apply to any product which, in Fluke Networks’ opinion, has 
been misused, abused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling.  Fluke Networks 
warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on 
non-defective media.  Fluke Networks does not warrant that software will be error free or operate without interruption. 

Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend 
a greater or different warranty on behalf of Fluke Networks.  Warranty support is available only if product is purchased through a Fluke Networks au-
thorized sales outlet or Buyer has paid the applicable international price.  Fluke Networks reserves the right to invoice Buyer for importation costs of 
repair/replacement parts when product purchased in one country is submitted for repair in another country. 

Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price, free of charge repair, or replacement of a 
defective product which is returned to a Fluke Networks authorized service center within the warranty period. 

To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then send the 
product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB destination).  Fluke Networks assumes no risk for 
damage in transit.  Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB destination).  If Fluke Networks de-
termines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal condition of operation or handling, or normal 
wear and tear of mechanical components, Fluke Networks will provide an estimate of repair costs and obtain authorization before commencing the 
work.  Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return trans-
portation charges (FOB Shipping point). 

THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT 
LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  FLUKE NETWORKS SHALL NOT BE LIABLE FOR 
ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. 

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential dam-
ages, the limitations and exclusions of this warranty may not apply to every buyer.  If any provision of this Warranty is held invalid or unenforceable by 
a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. 

4/04 

Fluke Networks 
PO Box 777 
Everett, WA 98206-0777 
USA 

Содержание etherscope II

Страница 1: ...2633787 May 2006 Rev 1 9 06 2006 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companies 99 Washington Street Melrose MA 02176 Fax 781 665...

Страница 2: ...r or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks author...

Страница 3: ...software prod uct like any other copyrighted material and copies must include the proper copyright notice 3 RESTRICTIONS You may not reverse engineer decompile or disassemble the software If the soft...

Страница 4: ...misapplication Any replacement software product will be warranted for the remained of the 90 day original warranty period or 30 days whichever is longer 8 NO OTHER WARRANTIES FLUKE NETWORKS DISCLAIMS...

Страница 5: ...Series II Network Assistant is powered in part by the Linux Operating System and other publicly available software A machine readable copy of the corresponding source code is available for the cost o...

Страница 6: ...s 3 Package Contents 4 Optional Accessories 9 Safety and Operational Information 10 Registering Your EtherScope Series IINetwork Assistant 12 Care and Maintenance 13 Contacting Fluke Networks 13 Befor...

Страница 7: ...Scope Network Assistant s Physical Features 24 Locating the Network Connections 24 Locating the External Interfaces 25 Locating the External Power Connection 25 Status LEDs 27 Power LED 29 The User In...

Страница 8: ...70 ITO Tests 71 Traffic Generator 71 Throughput Test 72 Configuring the Instrument for a Wired LAN 74 TCP IP Settings 75 802 1Q IP TOS Settings 76 802 1X Settings 78 Connection Log 79 Ethernet Setting...

Страница 9: ...Instrument Security Settings 101 Wireless General Settings 102 Wireless Authorization Settings 102 Wireless Problem Settings 104 Documenting Your Network LAN and WLAN 105 Saving a Report 105 Managing...

Страница 10: ...in Diagnosis 112 Signal Strength 112 WLAN Statistics 112 Tx Rx Rate 113 Accessing the Instrument Remotely LAN only 113 Using the Desktop Tools 117 Applications Menu 117 Tools Menu 118 Troubleshooting...

Страница 11: ...vii List of Tables Table Title Page 1 List of Standard Accessories 6 2 Optional Accessories 9 3 International Electrical Symbols 10...

Страница 12: ...27 5 Screen Level Help 35 6 LAN Test Results Screen 38 7 Testing Cables 40 8 Cable Verification Screen 42 9 Signal Verification Screen 46 10 Local Statistics Summary 47 11 Utilization History Screen...

Страница 13: ...ng the Fiber Adapter 84 24 Wireless LAN Test Results Screen 86 25 Channel Test Details Screen 89 26 Security Scan 97 27 Wireless Instrument Settings TCP IP Screen 99 28 Wireless Instrument Settings In...

Страница 14: ...stem the best source for answering questions and helping use the product to maintain your network and troubleshoot problems as they arise Introduction EtherScope Series II Network Assistant hereafter...

Страница 15: ...r touch sensitive screen is straightforward and intuitive Simply by tapping a screen button a navigation icon or other on screen element you can drill down and obtain more detailed information or perf...

Страница 16: ...he Internet Throughput Option ES2 PRO I a single integrated wired wireless analyzer that combines the features of the wired and wireless models described earlier This model includes the Internetwork T...

Страница 17: ...o make sure that the contents match each numbered standard accessory that is shown in Figure 1 and the accompanying list in Table 1 If any item is damaged call the carrier at once for inspection and r...

Страница 18: ...UT ILI ZA TIO N CO LLISION ER RO R TR AN SM IT CompactFlash Memory Card WLAN 3 2 1 4 7 8 11 10 12 6 5 LC 1 North American LC 3 Europe LC 4 UK LC 5 Swiss LC 6 Australia LC 7 South Africa 13 9 14 15 ei...

Страница 19: ...w holster C Stylus Stylus for use with the instrument s touch screen display D Storage Case Case for carrying and storing the instrument E External AC adapter charger power cord Input 90V 264V AC 50 6...

Страница 20: ...S2 PRO and ES2 PRO I models I ES2 SX Pro fiber adapter Fluke Networks EtherScope Fiber LAN Adapter 1000BASE SX This is a fiber accessory for the ES2 SX PRO and ES2 SX PRO I models Also available are t...

Страница 21: ...h cord N Universal adapter RJ 45 Female to female adapter It is intended to be used to connect a RJ 45 Ethernet cable from the instrument to a WireView wiremap adapter O External directional antenna D...

Страница 22: ...nal Accessories Item Description EtherScope Extended Test Kit The EtherScope Extended Test Kit includes additional accessories spare rechargeable battery external battery charger external mini keyboar...

Страница 23: ...trical Symbols j Not for connection to public telephone systems Complies to CSA C22 2 No 950 Canadian standards and UL 1950 US standards W Please read the manual for safety information Do not dispose...

Страница 24: ...t the case Look for cracked or missing plastic Do not operate the product around explosive gas vapor or dust Do not open the case There are no user serviceable parts inside Do not connect a telephone...

Страница 25: ...ng visitor follow the login instructions If need to set up an account click Create then follow the new account instructions 3 Click Register your product and fill out the online registration form As a...

Страница 26: ...the EtherScope Network Assistant on press the green On Off button This button is located on the right side of the instrument s front panel The front page Test Results screen is displayed see Figure 6...

Страница 27: ...e the point of the stylus to tap the screen We do not recommend that you use a pen or pencil or any other sharp object that might scratch the finish Selecting the LAN or WLAN Interface If your instrum...

Страница 28: ...d Power saving settings To do this tap to check an option Then for each option specify a time interval Adjust the brightness To do this tap and drag the slider control until the desired level of brigh...

Страница 29: ...e instrument automatically checks to determine whether a software update is available 6 When prompted tap to download the update files to the CompactFlash memory card Note All files and reports on the...

Страница 30: ...mpts to complete the recalibration Enabling Software Options If you purchased a software option for your EtherScope Network Assistant you received a proof of purchase code along with a software option...

Страница 31: ...in the upper left corner of the screen 2 From the drop down list select Instrument Settings 3 In the preview pane tap Version The Instrument Settings Version screen displays the versions of currently...

Страница 32: ...ould fully charge it before you begin using the instrument This is an important step because if the power source is interrupted while you are operating the instrument you will lose data Charging the B...

Страница 33: ...uspend mode This is a low power usage mode in which the instrument is not completely turned on or off While in Suspend mode the instrument cannot collect data To put the instrument in Suspend mode tap...

Страница 34: ...partment To install the battery insert it into the battery compartment Then press on the battery near the release tab until it locks into place Finally push the release tab toward the battery to secur...

Страница 35: ...sistant Before You Begin 23 LC 1 North American OR LC 3 Europe LC 4 UK LC 5 Swiss LC 6 Australia LC 7 South Africa LINK UTILIZATION COLLISION ERROR TRANSMIT eih30f eps Figure 2 Charging and Removing t...

Страница 36: ...tored in the right side panel near the green On Off button Figure 3 illustrates the EtherScope Network Assistant s physical features Locating the Network Connections The instrument s network connectio...

Страница 37: ...SB port connection for an accessory such as a keyboard or mouse SLOT 2 is located on the top side panel This interface accepts a CompactFlash type 1 and 2 memory card This memory card enables you to s...

Страница 38: ...ry Pack Power Jack USB Port Microphone Jack Headphone Jack Fiber LAN Connector RJ45 LAN Connector Kensington Lock left side DB9 Serial Port Strap Attach Stylus Compact Flash SLOT 2 PCMCIA CardBus SLOT...

Страница 39: ...Ds These LEDs provide instant visible feedback on the state of your network and indicate conditions relative to the type of of interface LAN RJ 45 or wireless you are testing This section describes th...

Страница 40: ...tes that errors have been detected on the local network segment Possible errors include the following Bad FCS a packet that has an invalid checksum Undersized packet a packet that has fewer than 64 by...

Страница 41: ...1 0 60 0 Red 61 100 COLLISION LED Amber indicates that a retry packet was received ERROR LED Red indicates an FCS error was detected in a received packet TRANSMIT LED Green indicates that packets are...

Страница 42: ...nformation for the item that is selected in the right main pane The preview pane may also have hyperlinks displayed in blue text that link to other screens in the user interface A main pane on the rig...

Страница 43: ...he connection Two solid arrows shown indicate a full duplex connection one solid and one outlined arrow represent a half duplex connection Fiber only reports the link speed full duplex always and the...

Страница 44: ...p icon Tap to display a menu containing the following selections Applications displays a submenu containing the instrument s desktop tools see Using the Desktop Tools on page 117 Reports displays a di...

Страница 45: ...r instructions The Clipboard icon is also located on the bottom right Tap it to display a menu with cut copy and paste options These options come in handy when you are working on screens requiring you...

Страница 46: ...Settings screen On this screen you can make the following changes to your instrument Appearance Changes the style and background color of the screen and the visual appearance of the buttons Date Time...

Страница 47: ...in the main pane To move through the information drag the scroll box The browser window is resizable so that you can view test information alongside the context sensitive Help text The main pane displ...

Страница 48: ...ts that include verifying the cable and signal gathering network utilization and bandwidth statistics and actively discovering networks services and devices using the network It reports its findings o...

Страница 49: ...utoTest Results on page 38 4 Make any needed configuration changes to match your testing environment See Configuring the Instrument for a Wired LAN on page 74 Connecting to a Wired Network To connect...

Страница 50: ...Test Results screen gives you at a glance visibility into the state of your network The main pane on the right displays the name of each test and reports its status Note the status icons that appear a...

Страница 51: ...k as the source of any problems you should first identify and eliminate any problems occurring at the physical or link layer of your network Results from the Connection test can help you isolate the s...

Страница 52: ...test terminated cable MDI MDI X Cable test WireView Adapter Universal Adapter Cable test open cable LINK UTILIZATION COLLISION ERROR TRANSMIT LINK UTILIZATION COLLISION ERROR TRANSMIT LINK UTILIZATIO...

Страница 53: ...e Networks Fiber Optic Meter be attached to the RJ45 port In the main pane tap the next to Connection to expand the list so that you can see these two tests Cable Verification Cable Verification inclu...

Страница 54: ...ify pairs The main pane displays results of the Cable Verification test A indicates that the instrument detects a valid cable A indicates that there is a problem with the cable To view detailed result...

Страница 55: ...hub or patch panel tap to set up and run a Cable Toner test Note This test requires a companion probe device for locating and tracing cable To test signal power and loss on a fiber optic cable select...

Страница 56: ...complete auto negotiation process When you exit the test the previous link configuration settings are restored To view initial autotest results select Signal Verification The preview pane shows the t...

Страница 57: ...ndard is not supported connection Press the Start Test button after checking this box to initiate this test The main pane see Figure 9 displays results from the four Signal Verification tests The test...

Страница 58: ...nals indicate the device supported signaling capabilities of the cable source link partner before the auto negation sequence begins The presence or absence of a signal is indicated by a green box or a...

Страница 59: ...presents a profile of the types of traffic seen on the network In the top half of the pane the types of traffic are classified for example unicast frames and collisions and the percentage of bandwidt...

Страница 60: ...on the local network segment and provides a breakout by percent of bandwidth utilization of all packets Top Talkers identifies the top 10 devices that are the highest consumers of bandwidth on the loc...

Страница 61: ...ization History screen Figure 11 is displayed epi50s bmp Figure 11 Utilization History Screen On this screen you can Look at the different types of traffic present on the network segment This informat...

Страница 62: ...icular period of time To do this tap the graph directly A white vertical bar marks the sampling period Note The graph is updated according to the frequency set in the Update every selection box To cha...

Страница 63: ...nd uses active SNMP discovery to determine the number of VLANs on your entire network If the instrument is connected to a port that is configured with 802 1Q VLAN tagging and the instrument is not so...

Страница 64: ...nt needs to be configured with the SNMP community strings being used on your network See Instrument Security Settings on page 79 to find out how to enter additional community strings If the instrument...

Страница 65: ...its DNS name IP address and key device status You can also see whether the device is experiencing any problems a Drag the scroll bar or tap the directional arrows at the bottom of the main pane to bri...

Страница 66: ...y shows utilization details relative percents of packets broadcasts and errors epi43s bmp Figure 12 Device Discovery Screen 4 Tap to view obtain detailed information about the device The Device Detail...

Страница 67: ...lly discover a device you can manually add the device to its discovery database After a device is added to the database the instrument keeps track of it and reports its statistics on the Device Discov...

Страница 68: ...ks into the following groups IP Subnets NetBIOS Domains IPX Networks Within each group you can also find out the number of devices discovered 2 To view detailed results for Network Discovery In the pr...

Страница 69: ...list of VLANs discovered The VLAN Statistics test monitors the frames only on the switch port interface that the instrument is connected to and generates a list of VLANs discovered 1 Tap VLAN Discover...

Страница 70: ...n tap to expand the list VLANs that have no associated switch interfaces simply display the switches that reference this VLAN 4 To get general information for a particular VLAN Interface select it The...

Страница 71: ...ap Nearest Switch epi66s bmp Figure 15 Nearest Switch Summary As shown in Figure 15 the preview pane displays the IP address of the switch along with its VLAN identifier and port number You can also s...

Страница 72: ...that is being monitored and the number of active ports on the switch In addition you can find out whether bandwidth utilization is excessive and whether the switch is experiencing any errors 2 Tap Not...

Страница 73: ...e The top portion of the preview pane shows the port number VLAN identifier speed of the interface and number of connected hosts The lower portion displays a graph that lets you see the relative perce...

Страница 74: ...hen you define a network device as key the instrument periodically checks its status up or down to determine its availability An occasional intermittent non response is ignored but if no response is r...

Страница 75: ...to check the box to mark it as a key device If the instrument did not discover the device a Tap b Tap Then in the Add Key Device box supply the IP address of the device c To ensure that the instrumen...

Страница 76: ...ection The preview pane shows the number of problems detected in each of the following severity groups Errors indicates that a severe problem exists with the network or the device the problem is disru...

Страница 77: ...e problem along with its assigned severity level Note You can sort the information in the main pane by tapping one of the column headings For example to sort on problem severity tap A directional arro...

Страница 78: ...status of the device or you can tap the SNMP System Group link to view SNMP information for the device Deleting a Problem from the Log To delete a problem from the log 1 Select the problem 2 Tap The d...

Страница 79: ...ests are in the RFC 2544 test group RFC 2544 Throughput measures the throughput speed and efficiency of your network RFC 2544 Latency measures how much time it takes for frames to travel through your...

Страница 80: ...upply the IP address of the device 5 Click Note Repeat this procedure to add additional devices for use in the individual tests The device name or IP address is added to the list of devices under the...

Страница 81: ...s apply only to the selected test and or device These settings override any global parameters set under RFC 2544 Tests To set parameters for an individual test or device 1 Select RFC 2544 Tests and th...

Страница 82: ...2544 Throughput and then tap 2 Use the radio buttons to select the Display Mode FPS Frames Sec or BPS Bits sec and View Mode table or graph To view Latency test results 1 Select a device under RFC 254...

Страница 83: ...hich can help you identify and isolate network performance issues Throughput a double ended test of bandwidth between two network nodes This test enables you to test throughput and evaluate a link s c...

Страница 84: ...ork Assistant a OneTouch Network Assistant with the Internet Throughput Option ITO installed or an OptiView INA V4 0 analyzer During the test both instruments simultaneously transmit packets to each o...

Страница 85: ...r of seconds the remote server should wait for additional throughput traffic from the local unit before timing out and terminating packet transmission 3 Tap Save Remote Throughput Settings Configuring...

Страница 86: ...AN Although EtherScope Network Assistant is designed to provide as much automated configuration as possible every network is different For the instrument to provide you with the best network analysis...

Страница 87: ...ings If DHCP is available the Instrument Settings TCP IP screen Figure 21 displays the address that the instrument is able to obtain If you want to manually configure the IP address or change the subn...

Страница 88: ...to configure the instrument for tagged VLAN 802 1Q and or IP Type of Service TOS operation These settings are applied globally to traffic from the instrument and remain in memory even after you turn o...

Страница 89: ...de the instrument extract and process this information from incoming packets b Supply the VLAN ID values range from 1 to 4095 c Set Priority select a value between 0 and 7 low to high to specify a pri...

Страница 90: ...types are None EAP TLS EAP GTC EAP MD5 EAP MSCHAPV2 PEAP GTC PEAP MD5 PEAP MSCHAPV2 PEAP TLS TTLS PAP TTLS CHAP TTLS MSCHAP TTLS MSCHAP V2 TTLS EAP MD5 TTLS EAP GTC TTLS EAP MSCHAP V2 TTLS EAP TLS Th...

Страница 91: ...s in the Forced Setting group Note An asterisk next to the value on the link button located in the lower left corner of the task bar indicates the speed duplex is a forced setting At the bottom of thi...

Страница 92: ...enters the password and logs in using the Login button On the Security screen you can also configure the instrument s SNMP community strings The default community strings are public private and secur...

Страница 93: ...ost Edit user defined devices lets you edit or delete existing user defined devices or add a new device that is either outside of the local broadcast domain or not being discovered Remote RFC 2544 ITO...

Страница 94: ...ing the connectivity of multiple office cubicles in a new installation In this mode the instrument automatically resets its discovery database when changing the network connection or when returning to...

Страница 95: ...and SFP fiber SX LX or ZX adapter are connected to the network at the same time and the instrument is trying to establish link the fiber connection has priority over the copper connection Installing a...

Страница 96: ...er W Caution Do not pull the fiber adapter without pressing the release tab or damage to the adapter may occur Gently insert the fiber adapter into the connector Remove fiber adapter dust cover Lock R...

Страница 97: ...t time you should configure a default SSID to automatically test link and to use active discovery methods See Wireless Instrument Security Settings on page 101 If operating the instrument in passive s...

Страница 98: ...ives you at a glance visibility into the state of your WLAN The main pane displays the name of each test and reports its status The icons along the right side give you a visual indication of the progr...

Страница 99: ...established an association with a wireless access point The instrument first scans the wireless network and then attempts to link to an AP that is configured with the default SSID After autotest runs...

Страница 100: ...ons from this screen see Configuring the Instrument for a Wireless LAN on page 98 for assistance Channels Test The Channels Test scans all channels in the 802 11a and 802 11 b g spectrums to locate ac...

Страница 101: ...rom the Channel Metric box The main pane redisplays the list of channels and for each channel reports results for the metric you selected 4 To focus in on a particular channel select it from the list...

Страница 102: ...information is continuously updated 2 To view channel details do one of the following To focus on a particular channel tap the desired hyperlink in the preview pane To focus on the busiest channel ta...

Страница 103: ...screen you can view bandwidth utilization and packet rates for all discovered devices To filter by channel or SSID select from the Channel or the SSID drop down list box respectively Device Discovery...

Страница 104: ...ain specific information for example the SSID and MAC address about each discovered device This screen also informs you whether any discovered device is experiencing problems 3 To obtain detailed info...

Страница 105: ...he channel it is active on You can also see utilization and security information for the device 2 Tap to obtain more detailed information about the AP On the Device details screen you can tap one of t...

Страница 106: ...vice The Device Details screen is displayed In the main pane you can view device specific information for example device type and security In the preview pane you can follow a hyperlink to view its si...

Страница 107: ...experiencing problems 3 To obtain greater detail tap a hyperlink or select a device and tap Site Survey The Site Survey test enables you to gather information on the APs in your WLAN You can use Site...

Страница 108: ...on is displayed in the preview pane OR Tap to view a list of all of the APs in your WLAN From this list you can select a particular AP and tap to view specifics If necessary you can run the diagnostic...

Страница 109: ...ion Settings on page 102 to find out how to set a device s authorization level The Security Scan test performs a security check on your network It identifies unauthorized rogue and unprotected devices...

Страница 110: ...to keep track of See Defining Key Devices on page 62 for instructions on setting up your list Problem Detection The Problem Detection test checks each discovered device in your WLAN for problems If a...

Страница 111: ...llowing sections Wireless TCP IP Settings To configure your wireless LAN s TCP IP settings tap the TCP IP hyperlink For information about this screen see TCP IP Settings on page 75 Wireless Security S...

Страница 112: ...anced Options then supply the desired information 3 Tap to save the changes Connection Log The Connection Log provides detail about the wireless authentication and authorization process and indicates...

Страница 113: ...ency range that you want the instrument to use Transmit Settings Enable Transmit default allows the instrument to link to the SSID specified on the Wireless Instrument Settings Wireless Security scree...

Страница 114: ...dd a new device to the instrument s discovery database If you have the Internet Throughput Option ITO installed you can enable the instrument as a remote throughput device In addition you can configur...

Страница 115: ...zation screen Figure 29 epi77s bmp Figure 29 Wireless Instrument Settings Authorization Screen 2 Select an individual device from the list or select an authorization level from the Select Current Leve...

Страница 116: ...above or below the setting you specify it responds by entering the problem into the Problem Log To set problem thresholds 1 Tap the Wireless Problems hyperlink to display the Wireless Instrument Sett...

Страница 117: ...Scope Network Assistant enables you to document the state of your network You can record network attributes baseline performance a device inventory a problem log and switch port statistics all in XML...

Страница 118: ...Manager 1 Tap 2 Select Applications from the drop down list 3 Tap File Manager to display the list of saved files Viewing a Report To view a report Note The following procedure shows you how to view...

Страница 119: ...from the CompactFlash memory card Performing a Site Survey WLAN only Another way to document your WLAN is to do a site survey A site survey can help ensure that your WLAN has the best coverage and has...

Страница 120: ...ute Trace Switch Route LAN only Wireless Throughput WLAN only Locate WLAN only Link WLAN only Login Diagnosis WLAN only Signal Strength WLAN only WLAN Statistics WLAN only Tx Rx Rate WLAN only You can...

Страница 121: ...ems or intermittent physical problems resulting from the cycling up or down of a link called route flapping can cause split routes Trace Switch Route The Trace Switch Route test can help you solve con...

Страница 122: ...d to test with any remote device that supports Ping To use Ping select Ping Then select the IP address of the target device from the drop down list box FTP used only with a device running an FTP serve...

Страница 123: ...tects the signal strength of a wireless device The closer you are to the device of interest the greater its signal strength Using these signal strength measurements you can home in on the location of...

Страница 124: ...tocol communication process between a selected client and the access point it is attempting to associate and authenticate with This test can help you troubleshoot problems that a device is having with...

Страница 125: ...ssion rates The information is presented in tabular form and is continuously updated according to the interval specified in the Update every box You can change the sampling period by selecting a diffe...

Страница 126: ...The instrument s IP address is located in the preview pane for the Test Results screen when the Connection test is highlighted The EtherScope Network Assistant web server home page Figure 32 is displ...

Страница 127: ...the Fluke Networks website Access the Help screens 3 To remotely access the instrument a Click b Use the keyboard to type the Remote Authentication password Then click Note The instrument s default f...

Страница 128: ...nk to view it User Interface Events that will Terminate a Remote Session The active TCP IP session between the remote user interface software and the instrument can be severed under the following cond...

Страница 129: ...hmetic operations such as addition and subtraction Calendar provides weekly and monthly views for scheduling events a Notes function enables you to add information about an event Clock displays the ti...

Страница 130: ...t you can check or change its configurations To connect select the desired device and then select Web Browser EtherScope Network Assistant s web browser Konquerer attempts to connect to the device Tel...

Страница 131: ...credentials It also encrypts the data sent between the logical and remote device Report displays reports on the CompactFlash memory card You can create a new report or delete a report Troubleshooting...

Страница 132: ...oes not display press and hold the On Off button for six seconds to completely shut down the instrument Then press the On Off button again to power the instrument back on Problem The IP Discovery and...

Страница 133: ...dtion you should see some activity on Transmit and or Utilization LEDs If the LEDs indicate no activity on the link do the following Check the Connection test results on the Test Results screen Select...

Страница 134: ...icon is displayed 3 Tap to view detailed results to see if you can determine what is causing the problem 4 To retest the cable tap Problem The battery charge state appears erratic or inconsistent The...

Страница 135: ...mm LED indicators mainframe 6 Battery Lithium Ion 7 2 V DC nominal 4 2 Ah Battery life Wired LAN mode approximately 4 hours Fiber Mode approximately 3 5 hours WLAN mode approximately 3 5 hours Extern...

Страница 136: ...ty Non Operating storage temperature 20 C to 60 C P Electromagnetic Interference complies to EN61326 Class A Criteria C j The product network interfaces are NOT FOR CONNECTION TO PUBLIC TELEPHONE SYST...

Страница 137: ...O IEC Class C and D Identifies and operates with the optional fiber adapter LX 1310nm 3 dBm 0 50 mW max SX 850nm 2 dBm 0 63 mW max and ZX 1550nm 4 dBm 2 5 mW max Cable Length Note Length accuracy depe...

Страница 138: ...hub switch or NIC All cable tests other than WireView wiremap and office locator ID are operational in the presence of datalink signal Fault Tolerance The RJ 45 10 100 1000 BASE T Ethernet connection...

Страница 139: ...79 B Back button 32 background screen color changing 34 bandwidth utilization 47 battery charging 20 conserving power 21 32 icon 33 installing 21 life wired versus wireless mode 20 battery icon 33 bl...

Страница 140: ...ce Switch Route 109 Tx Rx Rate 113 WLAN Statistics 112 WLAN Throughput 110 documentation 105 E ERROR LED 28 29 Errors icon 64 Ethernet settings 79 EtherScope Console icon 117 EtherScope Master Menu ic...

Страница 141: ...e 81 WLAN interface 102 General settings screen 102 H hardware software version information 19 headphone jack 25 Help context sensitive 35 language of changing 34 online documentation 35 Help button 3...

Страница 142: ...eror 118 L LAN Tests button 15 31 Language icon 34 LEDs 27 Light Power icon 33 LINK LED 27 29 Link Partner Signaling 46 Link test 112 Local Statistics 49 Local Statistics test 47 Locate test 111 Login...

Страница 143: ...5 wired interface auto negation Signals 46 autotest results 38 Cable Verification test 41 configuring EtherScope 74 connecting to 37 Connection test 39 DC Voltage Scan 45 Device Discovery test 52 Key...

Страница 144: ...SSID 100 standard accessories 5 status bar 32 stylus 6 stylus using 15 Suspend menu 32 Switch Scan 60 System Info icon 118 T TCP IP settings RJ 45 wired interface 75 wireless LAN 99 Telnet 118 Termin...

Страница 145: ...ice Discovery test 52 Key Devices test 62 local statistics 47 Nearest Switch test 59 Network Discovery test 56 Problem Log 63 security settings 79 Signal Verification tests 45 Switch Scan test 60 Traf...

Страница 146: ...cs 112 WLAN Tests button 15 31 WLAN Throughput test 110 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 FAX 781 665 0780 TestEquipmentDepot com Back to the Fluke Etherscope Pro...

Отзывы: