![Fluke E1M Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/fluke/e1m/e1m_user-manual_2309862091.webp)
Accessories
Electrical Accessories
91
12
12.1.7 Power Supply with Terminal Box (E-PS)
The terminal box for the power supply is designed to provide IP65 (NEMA-4) protection to the terminal block, see
section 12.1.4
, page 88, and a power supply for the sensor. The terminal box should be surface
mounted using the flanges and holes provided. It should be mounted in such a manner to allow the free flow of air
around the unit. Ambient temperatures for the terminal box should be kept within the range of 0 to 50°C (32 to
120°F), and humidity between 20 to 90%, non-condensing.
Technical data for the power supply:
AC input
100
– 240 VAC 50/60 Hz
DC output
24 VDC / 1.1 A
Figure 12-8: Power Supply with Terminal Box