l
(1)
Rotational angle covered by the shafts
l
(2)
Active clock measurement points taken (in this example set points attained)
l
(3)
Measurement quality attained
l
(4)
Hint (in this example set points attained)
l
(5)
Coupling results displayed as soon as the measurement quality reaches 40% (active
clock sector is orange)
l
(7)
Tap
to re-measure machines.
l
(8)
Tap
to view machine foot results.
Taking measurement points automatically
Measurement points may be taken automatically if the default setting item "Take points auto-
matically after stabilization" has been activated. The item 'Default settings' is found under
"Configuration".
The initial measurement is taken by tapping either the pulsating
M
or
after sta-
bilization.
When the rotational angle of the sensor and reflector is within the sector range, a series of
dots in circular motion (
1
) indicate the stabilization process. Once this occurs stop the rotation
of the shafts and wait for the pulsating
M
to appear.
The subsequent measurement points are taken automatically. The shafts are rotated to the
next sector range. Once stabilization begins, hold shafts at that position and wait for meas-
urement to be taken automatically. Repeat the procedure until all set active clock meas-
urement points are taken.
SHAFTALIGN touch
61
On-board help
Содержание db PRUFTECHNIK SHAFTALIGN touch
Страница 1: ...SHAFTALIGN touch On board help...
Страница 2: ...SHAFTALIGN touch On board help Version 2 3 Edition 07 2020 Part No DOC 26 200 EN...
Страница 24: ...SHAFTALIGN touch 23 On board help...
Страница 42: ...After target values have been entered tap to proceed SHAFTALIGN touch 41 On board help...
Страница 63: ...62 Version 2 3 On board help...
Страница 89: ...Note If no template is selected all template list options are unavailable 88 Version 2 3 On board help...
Страница 127: ...W Wireless connection 21 X XY view 81 XY View 53 SHAFTALIGN touch 126 On board help...