XY View
The XY View function is used to facilitate the centering of the laser beam on the position
detector before proceeding with measurement.
l
Tap the shown detector area
(1)
to directly access the XY View screen.
l
The XY View screen may be accessed using the menu item "XY View" which appears
when the "sensor area"
(2)
is tapped.
l
The XY View screen may be accessed using the menu item "XY View" which appears
when the reflector
(3)
is tapped.
Displayed are the absolute X,Y coordinates of the laser beam on the position detector, the
angle at which the sensor is currently positioned on the shaft and the sensor serial number.
Center the laser beam dot on the position detector using the adjustment knob and the adjust-
ment thumbwheel. In some cases it may be necessary to move the sensor along the support
posts or sideways by loosening the chain type bracket and slightly rotating it.
The "Set to zero" function may be used to check the effect of environmental and machinery
vibration on the measurement. Note that the "Set to zero" is active only when the laser beam
status [
1
] is "OK" or "Centered".
SHAFTALIGN touch
53
On-board help
Содержание db PRUFTECHNIK SHAFTALIGN touch
Страница 1: ...SHAFTALIGN touch On board help...
Страница 2: ...SHAFTALIGN touch On board help Version 2 3 Edition 07 2020 Part No DOC 26 200 EN...
Страница 24: ...SHAFTALIGN touch 23 On board help...
Страница 42: ...After target values have been entered tap to proceed SHAFTALIGN touch 41 On board help...
Страница 63: ...62 Version 2 3 On board help...
Страница 89: ...Note If no template is selected all template list options are unavailable 88 Version 2 3 On board help...
Страница 127: ...W Wireless connection 21 X XY view 81 XY View 53 SHAFTALIGN touch 126 On board help...