Safety Information

Warning

To prevent possible fire, electric shock, or personal injury:

Read all safety information before you use the 
Product.

Carefully read all instructions.

Do not connect the tester to telephony inputs, 
systems, or equipment, including ISDN inputs. 
Doing so is a misapplication of this product, which 
could result in damage to the tester and create a 
potential shock hazard to the user.

Do not open the case. You cannot repair or replace 
parts in the case.

Do not modify the Product.

Use only replacement parts that are approved by 
Fluke Networks.

Do not touch voltages > 30 V AC rms, 42 V AC peak, 
or 60 V DC.

Do not use the Product around explosive gas, vapor, 
or in damp or wet environments.

Use this Product indoors only.

Do not connect the Product to voltages that are 
higher than the maximum voltage rating for the 
Product.

For Products that have multiple connectors for 
different types of tests on copper cabling, 
disconnect unused test leads from the connectors 
before you do a test.

Use the Product only as specified, or the protection 
supplied by the Product can be compromised.

Conforms to relevant Russian standards.

KCC-REM-FKN-012001001: EMC approval for Korea
Class A Equipment (Industrial Broadcasting & 
Communication Equipment) 
This product meets requirements for industrial (Class A) 
electromagnetic wave equipment and the seller or user 
should take notice of it. This equipment is intended for use 
in business environments and is not to be used in homes.

This key turns the Product on and off.

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Содержание CableAnalyzer DSX-500

Страница 1: ...destruction to equipment or software See explanations in the manuals Warning Risk of fire electric shock or personal injury Do not connect this equipment to public communications networks such as tel...

Страница 2: ...amp or wet environments Use this Product indoors only Do not connect the Product to voltages that are higher than the maximum voltage rating for the Product For Products that have multiple connectors...

Страница 3: ...hot 50 C 122 F during the charge period The battery door must be closed and locked before you operate the Product Repair the Product before use if the battery leaks Recharge the batteries when the low...

Страница 4: ...the home screen Connector for the ac adapter The LED is red when the battery charges and green when the battery is fully charged The LED is yellow if the battery will not charge RJ45 connector Lets y...

Страница 5: ...ss to use the headset to speak to the person at the other end of the link Press again to adjust the volume To turn off the talk function hold down How to Certify Twisted Pair Cabling 1 Power the Teste...

Страница 6: ...e test setup panel To set up cable IDs and turn on Auto Save tap the Next ID panel To upload test results to LinkWare Live tap SYNC 3 Make Connections and Do a Test 3 1 Connect the testers to the link...

Страница 7: ...ter with permanent link adapter Remote with permanent link adapter Wall outlet Optional consolidation point Patch cord from hub or switch Start channel End channel Horizontal cabling Tester with chann...

Страница 8: ...e test passed or FIX LATER if the test failed 5 2 If the Cable ID box shows the correct ID tap SAVE To enter a cable ID tap the Cable ID box on the SAVE RESULT screen use the keyboard to enter a name...

Страница 9: ...instructions on how to do alien crosstalk tests install the AxTalk Analyzer software which is available on the Fluke Networks website then see the online help in the software Registration Registering...

Страница 10: ...d any other warranty on Fluke Networks behalf To obtain service during the warranty period contact your nearest Fluke Networks authorized service center to obtain return authorization information then...

Отзывы: