BT521
Users Manual
3-14
Typical Display
This is a typical display of discharge voltage measurement.
hpo052.jpg
Battery number:
The number to the left of / indicates the number of the battery that is
being tested. The number to the right of / indicates the total number of batteries in the
profile.
Progress bars:
The upper progress bar has eight cells. Each cell corresponds to one
round of discharge voltage measurement. The Product can store up to eight sets of
voltage test data as well as the intervals.
After one round of discharge voltage measurement is completed, this progress bar
moves forward by one cell. The interval between this and the last round of measurement
shows in this cell.
The lower progress bar is generated according to the total number of batteries in the
profile. Each cell corresponds to one battery. An empty cell indicates the corresponding
battery is not tested yet. A full cell indicates the corresponding battery has been tested
and the readings have been saved.
Cursors:
When you use
and
to move the two cursors, the number of currently
tested battery changes accordingly. If the cursors are moved to a cell that corresponds
to a battery with readings, the readings show under the progress bar.
Average readings:
After you have saved two or more sets of test readings, the Product
show the average readings, including average impedance and average voltage.