LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and 

service. The warranty period is three years and begins on the date of shipment. Parts, product repairs, and 

services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a 

Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's 

opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of 

operation or handling. Fluke warrants that software will operate substantially in accordance with its functional 

specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not 

warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only 

but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available 

only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable 

international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts 

when product purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or 

replacement of a defective product which is returned to a Fluke authorized service center within the warranty 

period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization 

information, then send the product to that service center, with a description of the difficulty, postage and 

insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the 

product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was 

caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, 

including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of 

mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before 

commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the 

Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR 

ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS 

OF DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation 

of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every 

buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of 

competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

11/99

Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.

Содержание 195112019382

Страница 1: ...III 1500V TRMS Clamp Meter Users Manual July 2021 English 2021 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respe...

Страница 2: ...ain warranty service contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty p...

Страница 3: ...ements 9 Hazardous Voltage Indicator 9 AC Voltage Measurement with Test Leads 9 DC Voltage Measurement with Test Leads 9 Resistance Continuity 10 Capacitance 10 Amps DC 11 Power DC 11 Amps AC 12 Amps...

Страница 4: ...ii 393 393 FC Users Manual Maintenance 17 How to Clean the Case 17 Environmental 17 Service 18 Specifications 18 General 18 Electrical 18 Mechanical 21 Environmental 22...

Страница 5: ...The iFlex provides increased display flexibility and allows measurements of awkward sized conductors and improved wire access The illustrations in this manual show the 393 FC The Clamp includes these...

Страница 6: ...ble in all regions supports the Clamp to wirelessly connect your Clamp with a mobile app The app shows the measurements and other data on your smartphone or tablet display You can share this data with...

Страница 7: ...p works with Apple and Android mobile products The app is available for download to your smart device from the Apple App Store and Google Play To use the Fluke Connect app 1 Open the FlukeConnect app...

Страница 8: ...e that the calibration seal in the battery compartment is not damaged If damaged the Product may not be safe to use Return the Product to Fluke for replacement of the seal W Caution To prevent damage...

Страница 9: ...for dc power current voltage resistance capacitance and frequency measurement functions INRUSH push to enter inrush mode Push a second time to exit inrush mode Integration time is 100 ms Push 2 s to...

Страница 10: ...maining memory 393 FC AC or DC measurement Inrush measurement Unit of measurement for voltage current dc power and resistance capacitance measurement Log mode is active 393 FC Unit of measurement for...

Страница 11: ...off is always disabled when you use the Min Max Avg Auto Hold Fluke Connect and Data Logging functions Backlight The display on the Clamp includes a backlight that improves the readability in dim wor...

Страница 12: ...oFF Disable Auto Backlight Off Hold down I as you turn ON Clamp rotate control knob and push Display shows LoFF View firmware version and light all LCD segments Any button ON rotate control knob Erase...

Страница 13: ...t the black test lead to the COM terminal and the red test lead to the VX terminal 3 Touch the probes to the test points of the circuit The display shows the ac voltage and the frequency DC Voltage Me...

Страница 14: ...Note A good capacitor stores an electrical charge and may remain energized after power is removed Before you touch the capacitor or make a measurement turn all power OFF use the Clamp to confirm that...

Страница 15: ...measurements 0 5 A the center dot in the icon is steady Power DC To measure dc power 1 Turn control knob to 2 Push to compensate zero for outside influences 3 Turn control knob to 4 Position the Clamp...

Страница 16: ...ach areas and works well with large conductors To use the iFlex Probe 1 Connect the iFlex Probe to the Clamp See Figure 2 2 Connect the flexible part of the iFlex Probe around the conductor If you ope...

Страница 17: ...ystem is connected and closed correctly or look for any damage If any foreign material is present the coupling system will not close properly Inspect the cable between the iFlex Probe and the Clamp fo...

Страница 18: ...ou a hazardous voltage is at the Product input When in HOLD mode push e again to resume normal operation with live readings Auto Hold To capture and hold the display reading automatically 1 Push e 2 s...

Страница 19: ...e the reading update recording continues This function works in current voltage and frequency modes 1 Push M to enter the Min Max Avg mode The maximum reading shows on the display 2 Continue to push M...

Страница 20: ...hows measurements from the connected Clamp on your smartphone or tablet display The app also saves the measurements in the Product internal memory and to the Fluke Connect Cloud storage With Fluke Con...

Страница 21: ...move the batteries if the Product is not used for an extended period of time or if stored in temperatures above 50 C If the batteries are not removed battery leakage may result How to Clean the Case W...

Страница 22: ...20 minutes Electrical Accuracy Accuracy is specified for 1 year after calibration at operating temperatures of 18 C to 28 C relative humidity at 0 to 75 Accuracy specifications take the form of of Rea...

Страница 23: ...itivity DC Current Range 999 9 A Resolution 0 1 A Accuracy 2 RD 5 digits 1 1 When using the ZERO function to compensate for offsets Distance from Optimum i2500 10 Flex i2500 18 Flex Error A 0 5 in 12...

Страница 24: ...quency Jaw Range 5 0 Hz to 500 0 Hz Resolution 0 1 Hz Accuracy 0 5 RD 5 digits Trigger Level 5 Hz to 10 Hz 10 A 10 Hz to 100 Hz 5 A 100 Hz to 500 Hz 10 A Amps Frequency Flexible Current Probe Range 5...

Страница 25: ...00 60 00 k Resolution 0 1 600 0 1 6000 0 01 k 60 00 k Accuracy 1 RD 5 digits Capacitance Range 100 0 F 1000 F Resolution 0 1 F 100 0 F 1 F 1000 F Accuracy 1 RD 5 digits Inrush Trigger Level 5 A Mechan...

Страница 26: ...and radiated disturbances Caution This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments Korea KCC Class A...