OVERRUN TIME
67
As soon as a delivery has been finished, the relays will be switched-off
but there may still be some flow till the valve is closed. During this
“overrun-time” all pulses will be counted as being part of the delivery. We
advise to program a time of one second or a couple of seconds,
depending on the response time of your system to close the valve. With
time 0.0 seconds, this function is disabled.
3.1.7.
EXPLANATION OF SETUP MENU 7 - STATUS
For external control of the F133-P, the unit can be started and/or stopped with two external switches.
STATUS INPUT 1
71
Following functions can be selected:
OFF:
status input is disabled.
START-function: do generate a short pulse to start a delivery.
STOP-function:
do generate a short pulse to stop the delivery.
CONTINUOUSLY: do switch the input continuously to execute a delivery;
first “disconnect” when the delivery is READY.
When it is interrupted during the batch, the unit goes
always to
“READY”. To start-up a new batch, the input
must be interrupted for at least 100msec. in-between
deliveries
STATUS INPUT 2
72
Following functions can be selected:
OFF:
status input is disabled.
PAUSE-function:
do generate a short pulse to pause the delivery.
STOP-function:
do generate a short pulse to stop the delivery.
BOTH-function:
do generate a short pulse to pause the delivery.
One more pulse will stop the delivery.
3.1.8.
EXPLANATION OF SETUP MENU 8 - COMMUNICATION (OPTION)
This product is designed for the connection to a communication network. Products with a
communication option do not include cyber security functions. Fluidwell cannot take any
responsibility for the cyber security, omissions or errors in the communication safety. To maintain a
secure operation, automation and control, it is the sole responsibility of the owner to install and
manage the appropriate safety measures to protect the network, the product and the communication
against any kind of security breaches.
The functions described below deal with hardware that is not part of the standard delivery.
Programming of these functions does not have any effect if this hardware has not been installed.
Consult Appendix C and the Modbus communication protocol description for a detailed explanation.
SPEED
81
This setting is used to set the Baudrate.
ADDRESS
82
This setting is used to set the communication address for the F133-P.
MODE
83
This setting is used to set the Modbus transmission mode. Select OFF to
disable the communication.
DATABITS
84
This setting determines for communication the number of databits.
Select 8 bit for BUS-RTU and 7 bits for BUS-ASC.
PARITY
85
As demanded by the connected equipment, select a parity bit (odd, even or none).
COMM. LOCK
86
With this setting, you determine if the unit will be locked after a delivery
till the unit will be released through communication (read appendix C
Communication variables)
Following can be selected:
disable:
function is disabled
time-out: the unit will be locked for 10 minutes or till communication
release. If nothing happens within 10 minutes, the unit will
release itself automatically.
full:
the unit can only be released through communication. When
the delivery is waiting to be released, the display will show
‘FINISHING’. Note that all keys and external controls are
disabled during this time.
When you select this option you can ONLY release the unit to normal
operation after each delivery through communications. If you accidentally
lock yourself out, please remove all power (including the battery) so the unit
will restart. You can then enter the setup-level to change this setting.