background image

12 

 

 

2.2 Programming 

Setting Current Time/Day  

Select POOL MODE Standby/Off 
 

(a)

 

Press

 

the CLOCK button. 

(b)

 

Press

 

DAY to change the current day.  

 

(c)

 

Press HOUR to move the Display cursor to the hour digits and then use the Up and Down arrows to the right of the 
display to change the current hour. 

(d)

 

Press

 

MIN to move the Display cursor to the min digits and then use the up and down arrows to

 

the right of the display 

to change the current minutes. 

(e)

 

Press

 

the CLOCK button to exit the clock setting mode. 

Setting Timers 

Your Chlorinator has 4 timers enabling you to set four different periods in which your chlorinator/pump will operate.  Different 
periods can be set for the weekend compared to weekdays.  Timers are set by entering a start time, and a period for how long 
you want to operate (i.e. Mon – Fri T1 On 14:00 and  Mon – Fri T1 Period 6:15 will run the chlorinator/pump during weekdays 
from 14:00 for 6.25 hours).  To set timers, do the following: 

 

(f)

 

Select

 

POOL MODE Standby/Off

 

(g)

 

Press

 

the TIMER button to step to the timer you want to set. 

(h)

 

Press

 

DAY button to step from Mon-Fri to Sat-Sun and vice versa.

 

(i)

 

Press

 

HOUR button to set the hour for the timer selected and use the Up/Down arrows to change the time.  NOTE: 

Hour digits go from Not Used and then 0 to 23.   If you don’t want to use this timer, select Not Used. 

(j)

 

Press

 

MIN button to select the minutes for the timer selected and use the Up/Down arrows to change the time.  Press 

the TIMER button to select the Period or another time and set as required

(k)

 

When

 

finished, press the TIMER button a number of times to scroll through the other times until you return to normal 

display.  This saves your new settings. 

(l)

 

Select

 

POOL MODE Auto 

 

Programming Recommendations 
Astral recommends that you use two timers, one for the morning and one for the evening and typically for periods of 2-5 hours 
for each. Your chlorinator is most effective if running in the early morning or evening when it is cooler (strong sunlight 
consumes more chlorine).  As a default, the control is set to come on at 08:00 and 16:00 both for periods of 4 hours. 
 
 
NOTE: Due to different time clock settings for weekday and weekends, the timer periods cannot be set to run past midnight 
(24:00 hours). If you cannot adjust the start time for a timer period, it is likely the period of run time is set to go beyond 24:00 
hours. To correct this, reduce the period run time first, then return to the start time and adjust. 
 
An example of this is if you have your timer period set to run for 4 hours, the chlorinator will not allow the start time to be set 
any later than 19:59. If you require the chlorinator to start at 20:00 hours, the running period must be less than 4 hours to 
prevent cross over to the next day. 

 

2.3 CHLORINE OUTPUT  

The Chlorine Output Control area of the user panel has three main functions: 

 

Содержание Astralpool VX7T

Страница 1: ...P OUT OF REACH OF CHILDREN REGISTRATION NO 31187 PEST CONTROL PRODUCT ACT WARNING Operating the VX7T Salt Chlorine Generator without water flow through the cell can cause a build up of flammable gas w...

Страница 2: ...This cell must only be used on this model of chlorine generating device Read the Label andthe Installation and Operation Manual for the VX7T Salt Chlorine Generator before using Fluidra Group Australi...

Страница 3: ...ING SAVE THESE INSTRUCTIONS Listed to UL 1081 Standard for Safety for Swimming Pool Pumps Filters and Chlorinators and CSA C22 2 No 218 1 Standard for Spas Hot Tubs and Associated Equipment Fluidra Gr...

Страница 4: ...on and additional run times are all selected and information is provided on the large liquid crystal display Intelligent Self Cleaning During operation the anode in the electrolytic cell attracts a bu...

Страница 5: ...tional Viron Connect you gain time clock operating hours saving you the total control of all your pool equipment chlorinator inconvenience of manually changing operating heater spa jets waterfalls and...

Страница 6: ...ine O ut pu t Level 16 3 2 Safety Backwash 17 3 3 Run Dry Safety Feature 18 3 4 General Operation PoolChemistry 18 3 5 Stabilizer 19 4 0 Chlorinator Maintenance and Troubleshooting 20 4 1 Cell Mainten...

Страница 7: ...by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to oper...

Страница 8: ...ine residuals can be protected from destruction by sunlight by addition of stabilizer cyanuric acid Heavy pool or spa usage and higher temperatures may require higher chlorine output to maintain prope...

Страница 9: ...with a medical condition should consult a physician before entering pool or spa water RISK OF HYPERTHERMIA Maximum spa water usage temperature is 40 C Bathing in spa water at 40 C should not exceed 15...

Страница 10: ...THIS PRODUCT 1 1 CHLORINATOR CONTROL UNIT INSTALLATION The VX7T Salt Chlorine Generator control has a Rating of IP24 enabling it to be installed outdoors Regulations state that the chlorinator contro...

Страница 11: ...fittings have been provided Make sure that the O rings are correctly fitted and the unions are done up tightly Direction of flow through the cell is critical unit must be plumbed with the water enteri...

Страница 12: ...er add salt to the skimmer box NOTE Plug the pump directly into a power outlet bypass the Chlorinator and run for 8 10 hours to ensure the salt is dissolved prior to running the chlorinator When the s...

Страница 13: ...11 Once programmed you will generally only use the User Mode and Chlorine Output control...

Страница 14: ...Used j Press MIN button to select the minutes for the timer selected and use the Up Down arrows to change the time Press the TIMER button to select the Period or another time and set as required k Wh...

Страница 15: ...ll may need replacing 2 4 User Mode The user mode buttons enable you to select Pool or Spa mode and to manually control the Chlorinator Pump Functions are as follows a POOL MODE Sends a message to oth...

Страница 16: ...the user panel set the desired output level or chlorine level As shown below the bottom right hand corner of the LCD display indicates the actual level as distinct from the set or desired output indi...

Страница 17: ...g your sand filter the pool water does not pass through the cell During the backwash and rinse process most chlorinators will build up potentially explosive hydrogen gas in the Chlorinator Cell The Sa...

Страница 18: ...the pump In some cases the pump will take more than three minutes to prime and for water flow to be detected by the chlorinator If this should occur simply start the pump again by pressing the Pool Mo...

Страница 19: ...ass pools and for other pools Total Alkalinity The ideal range is between 100 ppm and 120 ppm Salt Level Although salt is not consumed by the Chlorinator salt is lost during backwashing and when your...

Страница 20: ...t Chlorine Generator matching specific chlorinator model REGISTRATION NUMBER 31187 PEST CONTROL PRODUCTS ACT Cell Cleaning Instructions Close applicable valves Disconnect the chlorinator control unit...

Страница 21: ...19 Daily 30 100 ppm 30 100 ppm...

Страница 22: ...f unit to ensure satisfactory production of chlorine Adjust pins by separating if not held firmly in place Ensure no water contact is occurring with pins Three Monthly Check cell connections for leaks...

Страница 23: ...an Display blank No Power to chlorinator control unit Fuse blown Plug in chlorinator control unit and ensure power available Replace fuse 3 amp slow blow Low No chlorine production Cables not connecte...

Страница 24: ...ise no claim can be enforced against the carrier If concealed loss or damage is discovered you must notifythe carrier at once and request an inspection It is important that you do not discard the ship...

Отзывы: