background image

 

VX7T SALT CHLORINE GENERATOR  

1.0 GENERAL OVERVIEW 

Congratulations! You have purchased a VX7T  Salt Chlorine Generator. Please read the instructions carefully and your purchase will 
provide you with years of trouble free use. 
 
Your VX7T Salt Chlorine Generator works by converting some of the salt in your pool into chlorine which starts to destroy algae and 
bacteria in your pool water thereby sanitizing your pool.  As part of the process, the chlorine is converted back into salt and hence 
salt is not consumed. 
 
Your VX7T Salt Chlorine Generator control has many features to ensure simple operation of your chlorinator and filtration system.  It 
has a clever Spa mode to ensure that the right level of chlorine is produced whilst you are enjoying a spa. 
 
The VX7T Salt Chlorine Generator has an internal electronic time clock designed to operate the filtration pump up to 4 time periods 
Monday to Friday and 4 time periods Saturday/Sunday.   This model should not be connected to an external time clock where power 
is disconnected on a regular basis.   The VX7T Salt Chlorine Generator has a battery backup which is designed only to maintain timer 
setting memory in the event of an infrequent and short power interruption. 

TO  REDUCE  THE  RISK  OF  INJURY,  DO  NOT  PERMIT  CHILDREN  TO  USE  THIS 
PRODUCT. 

  

1.1 CHLORINATOR CONTROL UNIT INSTALLATION 

The VX7T Salt Chlorine Generator control has a Rating of IP24 enabling it to be installed outdoors.  Regulations state that the 
chlorinator control unit is not allowed to be located within 3 m (10 ft) of the pool water. 
 
The chlorinator control unit should be installed in a well-ventilated position ideally away from direct sunlight.  Ensure that the unit is 
not located near pool chemicals as fumes may damage the control. 
 
Included in the kit are two green masonry plugs and screws. When installing on a brick or concrete wall, use a 7 mm (9/32) masonry 
drill.  Mounting Screws should be 180 mm (7.1 in) apart and located at least 1.5 m(5 ft) above ground level.   
 
When installing the chlorinator control unit on a post, first attach a flat waterproof panel at least 300 mm wide by 500 mm long (12 in 
wide by 20 in long).  Make sure the unit is located centrally on the panel and sits flat. 
 
 
Have a qualified electrician install a weatherproof junction box with a GFCI protected outlet. Plug the chlorinator control unit power 
cable to the GFCI protected outlet. Then plug the power cable from the cell into to the chlorinator control unit. Finally, plug the 
power cable from the pump into the chlorinator control unit.

 

 

 

 
NoteThe pump current rating must not exceed 8 amps. 
 
WARNING 
The VX7T Salt Chlorine Generator must have the circulating pump connected to the pump outlet on the bottom of the chlorinator 
control unit. 

1.2 CELL INSTALLATION 

 

Содержание Astralpool VX7T

Страница 1: ...P OUT OF REACH OF CHILDREN REGISTRATION NO 31187 PEST CONTROL PRODUCT ACT WARNING Operating the VX7T Salt Chlorine Generator without water flow through the cell can cause a build up of flammable gas w...

Страница 2: ...This cell must only be used on this model of chlorine generating device Read the Label andthe Installation and Operation Manual for the VX7T Salt Chlorine Generator before using Fluidra Group Australi...

Страница 3: ...ING SAVE THESE INSTRUCTIONS Listed to UL 1081 Standard for Safety for Swimming Pool Pumps Filters and Chlorinators and CSA C22 2 No 218 1 Standard for Spas Hot Tubs and Associated Equipment Fluidra Gr...

Страница 4: ...on and additional run times are all selected and information is provided on the large liquid crystal display Intelligent Self Cleaning During operation the anode in the electrolytic cell attracts a bu...

Страница 5: ...tional Viron Connect you gain time clock operating hours saving you the total control of all your pool equipment chlorinator inconvenience of manually changing operating heater spa jets waterfalls and...

Страница 6: ...ine O ut pu t Level 16 3 2 Safety Backwash 17 3 3 Run Dry Safety Feature 18 3 4 General Operation PoolChemistry 18 3 5 Stabilizer 19 4 0 Chlorinator Maintenance and Troubleshooting 20 4 1 Cell Mainten...

Страница 7: ...by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to oper...

Страница 8: ...ine residuals can be protected from destruction by sunlight by addition of stabilizer cyanuric acid Heavy pool or spa usage and higher temperatures may require higher chlorine output to maintain prope...

Страница 9: ...with a medical condition should consult a physician before entering pool or spa water RISK OF HYPERTHERMIA Maximum spa water usage temperature is 40 C Bathing in spa water at 40 C should not exceed 15...

Страница 10: ...THIS PRODUCT 1 1 CHLORINATOR CONTROL UNIT INSTALLATION The VX7T Salt Chlorine Generator control has a Rating of IP24 enabling it to be installed outdoors Regulations state that the chlorinator contro...

Страница 11: ...fittings have been provided Make sure that the O rings are correctly fitted and the unions are done up tightly Direction of flow through the cell is critical unit must be plumbed with the water enteri...

Страница 12: ...er add salt to the skimmer box NOTE Plug the pump directly into a power outlet bypass the Chlorinator and run for 8 10 hours to ensure the salt is dissolved prior to running the chlorinator When the s...

Страница 13: ...11 Once programmed you will generally only use the User Mode and Chlorine Output control...

Страница 14: ...Used j Press MIN button to select the minutes for the timer selected and use the Up Down arrows to change the time Press the TIMER button to select the Period or another time and set as required k Wh...

Страница 15: ...ll may need replacing 2 4 User Mode The user mode buttons enable you to select Pool or Spa mode and to manually control the Chlorinator Pump Functions are as follows a POOL MODE Sends a message to oth...

Страница 16: ...the user panel set the desired output level or chlorine level As shown below the bottom right hand corner of the LCD display indicates the actual level as distinct from the set or desired output indi...

Страница 17: ...g your sand filter the pool water does not pass through the cell During the backwash and rinse process most chlorinators will build up potentially explosive hydrogen gas in the Chlorinator Cell The Sa...

Страница 18: ...the pump In some cases the pump will take more than three minutes to prime and for water flow to be detected by the chlorinator If this should occur simply start the pump again by pressing the Pool Mo...

Страница 19: ...ass pools and for other pools Total Alkalinity The ideal range is between 100 ppm and 120 ppm Salt Level Although salt is not consumed by the Chlorinator salt is lost during backwashing and when your...

Страница 20: ...t Chlorine Generator matching specific chlorinator model REGISTRATION NUMBER 31187 PEST CONTROL PRODUCTS ACT Cell Cleaning Instructions Close applicable valves Disconnect the chlorinator control unit...

Страница 21: ...19 Daily 30 100 ppm 30 100 ppm...

Страница 22: ...f unit to ensure satisfactory production of chlorine Adjust pins by separating if not held firmly in place Ensure no water contact is occurring with pins Three Monthly Check cell connections for leaks...

Страница 23: ...an Display blank No Power to chlorinator control unit Fuse blown Plug in chlorinator control unit and ensure power available Replace fuse 3 amp slow blow Low No chlorine production Cables not connecte...

Страница 24: ...ise no claim can be enforced against the carrier If concealed loss or damage is discovered you must notifythe carrier at once and request an inspection It is important that you do not discard the ship...