Inst.434 Viron XT Pool & Spa Pump V08_17
7
OPERATION OF CONTROL PANEL – VIRON P320 & P520 XT (CONT…)
Using the in built timer to operate pump with an AstralPool Chlorinator or EQ dosing unit
Factory Default Setting
1. The inbuilt timers are activated and will control the time the pump operates
2. Connectivity to AstralPool compliant Salt Chlorinators, EQ Chemical dosing controllers or Viron Connect
remote Controls i
s turned “off”
3. Use the
“auto” button to turn the pump on or off. When in on position, the pump will remain off until
the next timer period unless pressed again to manually on. If pump is turned to manually on, it will
continue to operate indefinitely.
If in the “Off” position (visible on the LCD), the pump will remain
indefinitely off. For timer operation, ensure the “auto” button is pressed so that the LCD screen displays
“auto”.
Setting the current Time
1. If connected to a compliant AstralPool Salt Chlorinator or EQ dosing controller connect data cable
between rear of pump and the chlorinator in EQ dosing unit.
2. Connect and turn power on to the pump and Chlorinator (or dosing unit)
3.
Have pump set in “MANUAL OFF”
4. Press
“MENU BUTTON” ONCE “CLK” appears and press “enter” to set time. Use
up and down
arrows to set the hour, press “enter” again to set minutes and then press “enter” again to set AM or PM.
5. Press
Auto
“enter” to accept
6. The LCD screen will quickly flash 3 times to indicate the new setting has been accepted.
Setting pump to operate independently of external AstralPool Compliant Chlorinator or Control System
1. Toggle
Menu until “CONF” is displayed on the LCD screen
2.
Press and HOLD “enter” for 3 seconds. “TMRS” will appear.
3.
Press “enter”
4. Press U
P or Down buttons to turn “TMRS ON”
5.
Press “enter” to accept
6. Press
“auto” to return to main menu.
Changing Low, Med and High Speed Settings
1. Select the Speed Button to be adjusted, Low, Medium or High. Respective LED will light up.
2. Alter the speed in increments of 25 RPM using the up and down arrows until the desired speed is
displayed on the screen. Respective “Speed 1”, Speed 2” or “Speed 3”, will flash while editing.
3. The new speed will automatically save after 2 seconds. Flashing will stop to signal save.
Setting filtration timer periods
1. Press Menu to go to PRIM setting.
2. Prime period is defaulted to 5 minutes and high speed. We recommend if your pump is installed at or
below water level, you change the PRIM to 2 minutes. Press “enter” and then Up or Down arrows to
change the prime speed.
Press “enter” to accept. Priming period will now be displayed.
3.
Use the Up or Down arrow to change the Priming period. Press “enter” to accept.
4.
Press Menu to go to TMR “timer settings” and press “enter” to change.
5. Timer 1 is factory set to start at 8 am. Use up or down arrows to change. Press High, Medium, or Low to
select the speed of the pump during Timer 1. On the LCD Screen High is represented by speed “1”,
medium by speed “2”, and Low by speed “3”.
6. Press Enter to move to the stop or end time of Timer 1. Use the up and down arrows to change the end of
Timer 1.
7. Timer 2 will now appear on the LCD Screen. Repeat instructions 4. to 6. Above.
8. Timer 3 will now appear but is factory pre-set to OFF. Moving any timer to midnight will turn that Timer
period off. Use the up and down arrows to activate the time and repeat process 4 and 5 above.
9. Timer 4 is also factory pre-set
to “off” but can be activated by using the up and down arrows.
10. Remember to select the speed you wish to operate during each timer period by pressing the High, Medium
or Low buttons while still in the Timer Start program.
Using the in built pump timers with a non compliant chlorinator or dosing unit.
1. We do not recommend the use of the pump timers when a non compliant chlorinator or chemical doser is
supplied water flow by the Viron P320 or P520 XT pump.
2. In this case, the pump operating hours should be controlled by the chlorinator time clock and the pump
plugged into the chlorinator. This is a safety measure provided for by most chlorinator manufacturers.
3. However, it is important to deactivate the inbuilt pump timers.
4.
Have Pump in “MANUAL OFF”
5. Toggle
Menu until “CONF” is displayed on the LCD screen
6.
Press and HOLD “enter” for 3 seconds
7. Toggle Menu un
til “TMR” appears.
8.
Press UP or Down buttons to turn “TMR OFF”
9.
Press “ENTER” to accept
10. Press
“AUTO” to return to main menu.