background image

Inst.434 Viron XT Pool & Spa Pump V08_17 

12 

MAINTENANCE 

Maintenance Schedule:    You new product incorporates moving parts and withstands high velocity water with 
chemicals in it.   Some of these parts will wear in the normal course of use and require regular checks and 
maintenance.    Performing these checks and maintenance will identify parts that have worn and require 
repair/replacement before further serious damage is sustained.   A small amount of regular care and attention to your 
pool equipment will help ensure long life and trouble free performance.
  
 
 

To protect against extremes of temperature, your unit is vented to allow expensive electronics to 
cool.   Ants and some insects are often attracted to the warmer, dry environment inside the enclosure.  We 
recommend that, with power turned off, you spray a surface insecticide on the surfaces surrounding the 
control to prevent ant and insect ingress.   Repeat every three months or as necessary

.

 

 

Timing 

Maintenance Check 

Service action (if required) 

Weekly or sooner 

Check and empty hair and lint basket 

Empty leaves and debris 

Three Monthly 

Check Lid O ring and inlet/outlet O rings for 
leaks 

Isolate Pump, turn power off, clean and 
grease O rings or replace if necessary 

Three Monthly 

Check surroundings for leaves, debris and 
flooding 
Check for inserts/ants 

Remove debris and rectify if any flooding 
 

Spray a surface insecticide on the 
surfaces around the unit to prevent ant 
and insect ingress. 

 

Three Monthly 

Check for leaks from underneath pump 

Call Service technician, repair or replace 
mechanical seal and motor bearings if 
necessary 

 

Important note: Regular maintenance is important to ensure long life and trouble free performance of your pool 
equipment.   If unable to perform the maintenance yourself, contact your local Astral Pool office who will arrange a trained 
service technician to perform the maintenance for you. 

 

 

 

Содержание Astralpool Viron P320 XT

Страница 1: ...ING INSTRUCTIONS sales astralpool com au www astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Viron P320 XT...

Страница 2: ...EALER OPERATING PUMP IN OVERDRIVE MODE WILL CREATE VERY HIGH WATER PRESSURE ENSURE ALL CONNECTIONS ARE WATER TIGHT STAND CLEAR OF ANY FILTER LIDS AND OTHER EQUIPMENT IN THE SYSTEM WHEN OPERATING IN OV...

Страница 3: ...ded which will prevent cooling airflow from fan Overheating due to lack of cooling voids warranty 5 Within reach of power point without extension plugs liable to corrosion shorting etc 6 At a minimum...

Страница 4: ...ulty seal cracked lint pot lid etc 7 The Viron XT has 3 factory pre set speed settings Low Medium and High High should be used when backwashing manually vacuuming the pool or operating spa jets or som...

Страница 5: ...to ensure that a you have adequate chlorine and b the water in your pool looks clear and inviting If you have any doubts take a sample of water to your local pool shop for a water analysis Examples o...

Страница 6: ...ed low medium high for each timer period Displays actual RPM of motor and low medium and high speed can be adjusted to suit your pool Time clock and timer periods can be disabled if connected to an ex...

Страница 7: ...flash while editing 3 The new speed will automatically save after 2 seconds Flashing will stop to signal save Setting filtration timer periods 1 Press Menu to go to PRIM setting 2 Prime period is defa...

Страница 8: ...g the external control to set the pump operating hours so the pump timer must be turned off 4 Press enter to accept 5 Toggle menu until SYS system appears Press the up or down button and turn to ON Th...

Страница 9: ...um or high speed can be selected for each timer period Data cable connecting pump to chlorinator via Comms interface module XTPump to be set up with timer periods deactivated Pump speed can be changed...

Страница 10: ...er To operate a suction cleaner on your pump 1 Choose the speed button low medium or high on which the pump will operate when the suction cleaner is connected 2 Allow pump to operate for a minimum of...

Страница 11: ...nt to activate the pressure switch and control circuit within the heater If using a compatible AstralPool Gas Heater you can automatically increase the speed of your Viron XT pump to ensure the water...

Страница 12: ...ces surrounding the control to prevent ant and insect ingress Repeat every three months or as necessary Timing Maintenance Check Service action if required Weekly or sooner Check and empty hair and li...

Страница 13: ...E E TIM E R 3 STOP TIM E E TIM E R 4 STA RT TIM E E TIM E R 4 STOP TIM E M PRIM M OFF ON CONF E ON OFF E E CURRENT PRIM E SPEED NEW PRIM E SPEED NEW PRIM E DURATION CURRENT PRIM E DURATION E CURRENT I...

Страница 14: ...e alleged defect and c appropriate documentation such as historical and maintenance records 3 The customer must make the Product available to AstralPool or its Authorised AstralPool Service Agent for...

Страница 15: ...performance or life of the equipment will void the warranty Insect infestation or penetration by sand dust or other foreign bodies will void warranty Where in field labor warranty is provided a 20km...

Страница 16: ...t 434 Viron XT Pool Spa Pump V08_17 16 INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIO...

Отзывы: