background image

Inst.434 Viron XT Pool & Spa Pump V08_17 

Serious injury or death may occur if this product is not used, operated or installed according to these instructions and 
relevant Australian standards.

 

 

 

THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS.  PLEASE ENSURE YOUNG 
CHILDREN ARE SUPERVISED SO THAT THEY DO NOT PLAY WITH THE APPLIANCE.  

 

PUMP PRODUCES HIGH PRESSURES – STAND CLEAR OF PUMP AND ALL FILTRATION EQUIPMENT DURING START UP 

 

 

PUMP MUST ONLY BE INSTALLED BY A QUALIFIED POOL INDUSTRY PROFESSIONAL.   INSTALLERS, OPERATORS 
AND OWNERS MUST READ THESE INSTRUCTIONS BEFORE USE. 

 

PUMP  AUTOMATICALLY  RESTARTS  AFTER  HIGH  LIMIT  OPERATION,  DISCONNECT  POWER  TO  PUMP  BEFORE 
MAINTENANCE OR REPAIR 

 

INCORRECT SETTING OF  THE SPEEDS ON THIS PUMP MAY CAUSE ADVERSE FILTRATION OR OPERATION OF THE 
SWIMMING  POOL  OR  SPA.    ENSURE  PUMP  IS  INSTALLED,  SET  AND  COMMISSIONED  BY  AN  AUTHORISED 
ASTRALPOOL DEALER. 

OPERATING PUMP IN OVERDRIVE MODE WILL CREATE VERY HIGH WATER PRESSURE ENSURE ALL CONNECTIONS 

ARE WATER TIGHT  STAND CLEAR OF ANY FILTER LIDS AND OTHER EQUIPMENT IN THE SYSTEM WHEN OPERATING 
IN OVERDRIVE 

 

GENERAL 

 
The Viron XT Pool Pump is a unique variable-speed AC motor combined with an energy efficient pump wet end.   When 
installed and plumbed correctly, the Viron XT will significantly reduce operating costs, lower noise levels and reduce 
greenhouse emissions. 
 
The Viron XT Pool Pump range is available in a variety of models, with the following factory set speeds which offer 
approximate flow rates: 
 

Model 

High 

Medium 

Low 

Viron P320 XT 

320 lpm 

206 lpm 

128 lpm 

Viron P520 XT 

520 lpm 

426 lpm 

200 lpm 

 

(Flow rates based on a maximum speed at 8 m total dynamic head). 
 

Each speed can be easily changed to suit your pool size, filter, plumbing and application.  The Viron XT Series pumps must 
be installed by a pool professional trained by AstralPool to ensure it has been selected for the correct application, correctly 
installed and set up to suit your pool and its operation fully explained to you. 

 

 

Содержание Astralpool Viron P320 XT

Страница 1: ...ING INSTRUCTIONS sales astralpool com au www astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Viron P320 XT...

Страница 2: ...EALER OPERATING PUMP IN OVERDRIVE MODE WILL CREATE VERY HIGH WATER PRESSURE ENSURE ALL CONNECTIONS ARE WATER TIGHT STAND CLEAR OF ANY FILTER LIDS AND OTHER EQUIPMENT IN THE SYSTEM WHEN OPERATING IN OV...

Страница 3: ...ded which will prevent cooling airflow from fan Overheating due to lack of cooling voids warranty 5 Within reach of power point without extension plugs liable to corrosion shorting etc 6 At a minimum...

Страница 4: ...ulty seal cracked lint pot lid etc 7 The Viron XT has 3 factory pre set speed settings Low Medium and High High should be used when backwashing manually vacuuming the pool or operating spa jets or som...

Страница 5: ...to ensure that a you have adequate chlorine and b the water in your pool looks clear and inviting If you have any doubts take a sample of water to your local pool shop for a water analysis Examples o...

Страница 6: ...ed low medium high for each timer period Displays actual RPM of motor and low medium and high speed can be adjusted to suit your pool Time clock and timer periods can be disabled if connected to an ex...

Страница 7: ...flash while editing 3 The new speed will automatically save after 2 seconds Flashing will stop to signal save Setting filtration timer periods 1 Press Menu to go to PRIM setting 2 Prime period is defa...

Страница 8: ...g the external control to set the pump operating hours so the pump timer must be turned off 4 Press enter to accept 5 Toggle menu until SYS system appears Press the up or down button and turn to ON Th...

Страница 9: ...um or high speed can be selected for each timer period Data cable connecting pump to chlorinator via Comms interface module XTPump to be set up with timer periods deactivated Pump speed can be changed...

Страница 10: ...er To operate a suction cleaner on your pump 1 Choose the speed button low medium or high on which the pump will operate when the suction cleaner is connected 2 Allow pump to operate for a minimum of...

Страница 11: ...nt to activate the pressure switch and control circuit within the heater If using a compatible AstralPool Gas Heater you can automatically increase the speed of your Viron XT pump to ensure the water...

Страница 12: ...ces surrounding the control to prevent ant and insect ingress Repeat every three months or as necessary Timing Maintenance Check Service action if required Weekly or sooner Check and empty hair and li...

Страница 13: ...E E TIM E R 3 STOP TIM E E TIM E R 4 STA RT TIM E E TIM E R 4 STOP TIM E M PRIM M OFF ON CONF E ON OFF E E CURRENT PRIM E SPEED NEW PRIM E SPEED NEW PRIM E DURATION CURRENT PRIM E DURATION E CURRENT I...

Страница 14: ...e alleged defect and c appropriate documentation such as historical and maintenance records 3 The customer must make the Product available to AstralPool or its Authorised AstralPool Service Agent for...

Страница 15: ...performance or life of the equipment will void the warranty Insect infestation or penetration by sand dust or other foreign bodies will void warranty Where in field labor warranty is provided a 20km...

Страница 16: ...t 434 Viron XT Pool Spa Pump V08_17 16 INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIO...

Отзывы: