  5. MAINTENANCE AND INSPECTION 

 

 

Check the water supply device and the release often. You should avoid the condition of no water or 
air entering into system, as this will influence unit's performance and reliability.

 

You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the dirty of 
clogged filter.

 

The area around the unit should be dry, clean and well ventilated. Clean the side heating 
exchanger regularly to maintain good heat exchange as conserve energy .

 

The operation pressure of the refrigerant system should only be serviced by a certified 
technician .

 

Check the power supply and cable connection often,.Should the unit begin to operate 
abnormally, switch it off and contact the qualified technician.

 

Discharge all water in the water pump and water system ,so that freezing of the water in the pump or 
water system does not occur. You should discharge the water at the bottom of

 

water pump if the unit will not be used for an extended period of time. You should check the unit 
thoroughly and fill the system with water fully before using it for the first time after a

 

 

Checks to the area

 

Prior to beginning work on systems containing flammable refrigerants, safety checks are 
necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating

 

system, the following precautions shall be complied with prior to conducting work on the system. 
prolonged period of no usage.

 

Work procedure

 

Work shall be undertaken under a controlled procedure so as to minimise the risk of a 
flammable gas or vapour being present while the work is being performed.

 

Work procedure

 

Work shall be undertaken under a controlled procedure so as to minimise the risk of a 
flammable gas or vapour being present while the work is being performed.

 

General work area

 

All maintenance staff and others working in the local area shall be instructed on the nature of work 
being carried out. Work in confined spaces shall be avoided. The area around the workspace shall 
be sectioned off. Ensure that the conditions within the area have been

 

made safe by control of flammable material.

 

General work area

 

All maintenance staff and others working in the local area shall be instructed on the nature of work 
being carried out. Work in confined spaces shall be avoided. The area around the workspace shall 
be sectioned off. Ensure that the conditions within the area have been

 

made safe by control of flammable material.

 

Checking for presence of refrigerant

 

The area shall be checked with an appropriate refrigerant detector prior to and during work, to 
ensure the technician is aware of potentially flammable atmospheres. Ensure that the

 

leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-
sparking, adequately sealed or intrinsically safe.

 

Presence of fire extinguisher

 

If  any  hot  work  is  to  be  conducted  on  the  refrigeration  equipment  or  any  associated  parts, 
appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire 
extinguisher adjacent to the charging

 

Содержание 78568

Страница 1: ...intended for use by young children 3 08 2017 ECO RANGE INVERTER HEAT PUMPS Installation Instruction manual INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Eco Range...

Страница 2: ......

Страница 3: ...ool Heat Pumps Electrical Wiring 10 3 6 Initial Start up of the Unit 10 4 Use and Operation Instruction 11 4 1 Interface display 11 4 2 Key and icon function instruction 11 4 3 Startup shutdown 13 4 4...

Страница 4: ...t type unit The indoor unit can be Discretely hidden or semi hidden to suit a luxury house Our heat pump has following characteristics 1 Durable The heat exchanger is made of PVC Titanium tube which c...

Страница 5: ...liance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Appliance shal...

Страница 6: ...ful life must be handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 D...

Страница 7: ...g Power Input kW 0 2 1 25 0 27 1 72 COP 4 5 3 2 4 5 3 2 Power Supply 220 240V 50Hz 220 240V 50Hz Compressor Quantity 1 1 Compressor rotary rotary Fan Number 1 1 Noise dB A 38 50 39 51 Water Connection...

Страница 8: ...3 2 18 COP 4 8 3 3 Power Supply 220 240V 50Hz Compressor Quantity 1 Compressor rotary Fan Number 1 Noise dB A 42 53 Water Connection mm 48 3 Water Flow Volume m3 h 3 5 Water Pressure Drop max kPa 4 Un...

Страница 9: ...6 545 2 SPECIFICATION 2 2 The dimensions for Swimming Pool Heat Pump Unit UNIT 78566 78567 78568 unit mm 1000 Water outlet 48 3 Water inlet 48 3 418 350 97 605...

Страница 10: ...pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary that the water in pipe is higher than the pool surface The schematic diagram is forreference only Please che...

Страница 11: ...inlet These locations deny the unit of a continuous source of fresh air which reduces it efficiency and may prevent adequate heat delivery 3 3 How Close To Your Pool Normally the pool heat pump is ins...

Страница 12: ...to provide easier access should servicing be required To pool PVC COUPLER RECOMMENDED Provided From pump CONDENSATION DRAIN BARB FTG Condensation Since the Heat pump cools down the air about 4 5 wate...

Страница 13: ...nitial startup of the Unit NOTE In order for the unit to heat the pool or spa the filter pump must be running to circulate water through the heat exchanger Start up Procedure After installation is com...

Страница 14: ...effective and used to enter and exit the mute mode with one click Mode key It is used to switch the unit mode temperature setting and parameter setting On off key It is used to carry out startup shutd...

Страница 15: ...sh Or else it is off Timing symbol It will display after the user sets the timing and multiple timing intervals can be set Water outlet symbol When the axillary display area displays the water outlet...

Страница 16: ...rface When it displays with half screen off or full screen off click any key for returning to ON OFF main interface When the unit is started under the control of wire controller if using the emergency...

Страница 17: ...g During the defrosting mode switch is available And when switching the mode the unit won t work under a new mode until defrosting is completed 4 5 Temperature setting Notes Under the temperature sett...

Страница 18: ...lay among timer ON1 OFF1 ON2 and OFF2 4 Use andOperation Instruction 4 6 Clock setting 6 1 System time setting Notes Under the clock setting interface if there is no operation for 20 s the system will...

Страница 19: ...lay among timer ON1 OFF1 ON2 and OFF2 4 Use andOperation Instruction 4 6 Clock setting 6 1 System time setting Notes Under the clock setting interface if there is no operation for 20 s the system will...

Страница 20: ...2 1 cancel the Timer ON OFF as below Take ON1 for example 2 To cancel the first stage timing switch cancel both ON and To cancel the second stage timing switch cancel both ON2 and To cancel the two st...

Страница 21: ...silent Keep long press of fo r 2 s Short press or 4 Use andOperation Instruction 4 7 Silent setting 7 1 One click silent function Notes 1 If one click silent and timming silentaare stared at the same...

Страница 22: ...em Check the pipe water flow and water pump Anti freezing Prot E07 Water flow is not enough Checkth ep ipew aterfl owa ndw hether waters ystemi sja mmedo rn ot Winter Primary Anti freezing Prot E19 Th...

Страница 23: ...nput voltagemeasurement Inv Sampling Volt F11 The input voltage sampling fault Checkand adjustthe current measurement Comm Err DSP PFC F12 DSP and PFC connect fault Checkthe communicationconnection In...

Страница 24: ...Default 27 27 27 Remarks Adjustable Adjustable Adjustable 4 Use and Operation Instruction 10 2 Parameter list Meaning 21...

Страница 25: ...4 Use and Operation Instruction 4 11 Main board 22...

Страница 26: ...23 4 Use and Operation Instruction Main board of the input and output interface instructions below Number Sign Meaning 22 23 Color line controller communication...

Страница 27: ...ge Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed Work procedure Work shal...

Страница 28: ...times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to instal...

Страница 29: ...only with parts specified by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak Cabling Check that cabling will not be subject to wear corrosion exces...

Страница 30: ...igerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holdin...

Страница 31: ...e in accordance with manufacturer s instructions h Do not overfill cylinders No more than 80 volume liquid charge i Do not exceed the maximum working pressure of the cylinder even temporarily j When t...

Страница 32: ...0A 30mA less than 0 1 sec 186 224A 2 95mm2 95mm2 280A 30mA less than 0 1 sec 2 Three phase unit Nameplate maximum current Phase line Earth line MCB Creepage protector Signal line No more than 10A 3 1...

Страница 33: ...0 3 0 5 0 8 1 1 3 1 5 1 8 2 2 3 Temperature R410A 51 3 20 9 4 11 19 24 31 35 39 Temperature R32 52 5 20 9 3 5 10 18 23 29 5 33 3 38 7 Pressure MPa 2 5 2 8 3 3 3 3 5 3 8 4 4 5 5 5 5 Temperature R410A 4...

Страница 34: ...Note...

Страница 35: ...Note...

Страница 36: ......

Отзывы: