 1. PREFACE 

 

 

Caution & Warning

 

1.  The unit can only be repaired by qualified installer centre personnel or an authorised 

dealer. for Europe market

 

2. 

 

This  appliance  is not intended  for use  by persons  (including children)  with reduced  physical 

sensory  or mental  capabilities,  or lack of experience  and knowledge,  unless they have  been 
given  supervision  or instruction concerning  use  of the appliance  by a person  responsible  for 
their safety. for Europe  market

 

Children should be supervised to ensure that they do not play with the appliance.

 

3. 

 

Please make sure that the unit and power connection have good earthing, otherwise may 

cause electrical shock.

 

4. 

 

If the supply cord is damaged, it must be replaced by the manufacturer or our service agent 

or similarly qualified person in order to avoid a hazard.

 

5.  Directive 2002/96/EC (WEEE):

 

The symbol depicting a crossed-out waste bin that is underneath the appliance indicates that this 
product, at the end of its useful life, must be handled separately from domestic waste, must be 
taken to a recycling centre for electric and electronic devices or handed back to the dealer when 
purchasing an equivalent appliance.

 

6. 

 

Directive 2002/95/EC (RoHs): This product is compliant with directive 2002/95/EC (RoHs) 

concerning restrictions for the use of harmful substances in electric and electronic  devices.

 

7.  The unit CANNOT be installed near the flammable gas. Once there is any leakage of the gas

 

, fire can be occur.

 

8. 

 

Make sure that there is circuit breaker for the unit, lack of circuit breaker can lead to 

electrical shock or fire.

 

9. 

 

The heat pump located inside the unit is equipped with an over-load protection system. It 

does not allow for the unit to start for at least 3 minutes from a previous stoppage.

 

10.The unit can only be repaired by the qualified personnel of an installer center or an 

authorized dealer. for North America market

 

11. Installation must be performed in accordance with the NEC/CEC by authorized person only. 

for North America market

 

12.  USE SUPPLY WIRES SUITABLE FOR 75 

 

.

 

13.  Caution: Single wall heat exchanger, not suitable for potable water connection.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

3

 

Содержание 78568

Страница 1: ...intended for use by young children 3 08 2017 ECO RANGE INVERTER HEAT PUMPS Installation Instruction manual INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS Eco Range...

Страница 2: ......

Страница 3: ...ool Heat Pumps Electrical Wiring 10 3 6 Initial Start up of the Unit 10 4 Use and Operation Instruction 11 4 1 Interface display 11 4 2 Key and icon function instruction 11 4 3 Startup shutdown 13 4 4...

Страница 4: ...t type unit The indoor unit can be Discretely hidden or semi hidden to suit a luxury house Our heat pump has following characteristics 1 Durable The heat exchanger is made of PVC Titanium tube which c...

Страница 5: ...liance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Appliance shal...

Страница 6: ...ful life must be handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 D...

Страница 7: ...g Power Input kW 0 2 1 25 0 27 1 72 COP 4 5 3 2 4 5 3 2 Power Supply 220 240V 50Hz 220 240V 50Hz Compressor Quantity 1 1 Compressor rotary rotary Fan Number 1 1 Noise dB A 38 50 39 51 Water Connection...

Страница 8: ...3 2 18 COP 4 8 3 3 Power Supply 220 240V 50Hz Compressor Quantity 1 Compressor rotary Fan Number 1 Noise dB A 42 53 Water Connection mm 48 3 Water Flow Volume m3 h 3 5 Water Pressure Drop max kPa 4 Un...

Страница 9: ...6 545 2 SPECIFICATION 2 2 The dimensions for Swimming Pool Heat Pump Unit UNIT 78566 78567 78568 unit mm 1000 Water outlet 48 3 Water inlet 48 3 418 350 97 605...

Страница 10: ...pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary that the water in pipe is higher than the pool surface The schematic diagram is forreference only Please che...

Страница 11: ...inlet These locations deny the unit of a continuous source of fresh air which reduces it efficiency and may prevent adequate heat delivery 3 3 How Close To Your Pool Normally the pool heat pump is ins...

Страница 12: ...to provide easier access should servicing be required To pool PVC COUPLER RECOMMENDED Provided From pump CONDENSATION DRAIN BARB FTG Condensation Since the Heat pump cools down the air about 4 5 wate...

Страница 13: ...nitial startup of the Unit NOTE In order for the unit to heat the pool or spa the filter pump must be running to circulate water through the heat exchanger Start up Procedure After installation is com...

Страница 14: ...effective and used to enter and exit the mute mode with one click Mode key It is used to switch the unit mode temperature setting and parameter setting On off key It is used to carry out startup shutd...

Страница 15: ...sh Or else it is off Timing symbol It will display after the user sets the timing and multiple timing intervals can be set Water outlet symbol When the axillary display area displays the water outlet...

Страница 16: ...rface When it displays with half screen off or full screen off click any key for returning to ON OFF main interface When the unit is started under the control of wire controller if using the emergency...

Страница 17: ...g During the defrosting mode switch is available And when switching the mode the unit won t work under a new mode until defrosting is completed 4 5 Temperature setting Notes Under the temperature sett...

Страница 18: ...lay among timer ON1 OFF1 ON2 and OFF2 4 Use andOperation Instruction 4 6 Clock setting 6 1 System time setting Notes Under the clock setting interface if there is no operation for 20 s the system will...

Страница 19: ...lay among timer ON1 OFF1 ON2 and OFF2 4 Use andOperation Instruction 4 6 Clock setting 6 1 System time setting Notes Under the clock setting interface if there is no operation for 20 s the system will...

Страница 20: ...2 1 cancel the Timer ON OFF as below Take ON1 for example 2 To cancel the first stage timing switch cancel both ON and To cancel the second stage timing switch cancel both ON2 and To cancel the two st...

Страница 21: ...silent Keep long press of fo r 2 s Short press or 4 Use andOperation Instruction 4 7 Silent setting 7 1 One click silent function Notes 1 If one click silent and timming silentaare stared at the same...

Страница 22: ...em Check the pipe water flow and water pump Anti freezing Prot E07 Water flow is not enough Checkth ep ipew aterfl owa ndw hether waters ystemi sja mmedo rn ot Winter Primary Anti freezing Prot E19 Th...

Страница 23: ...nput voltagemeasurement Inv Sampling Volt F11 The input voltage sampling fault Checkand adjustthe current measurement Comm Err DSP PFC F12 DSP and PFC connect fault Checkthe communicationconnection In...

Страница 24: ...Default 27 27 27 Remarks Adjustable Adjustable Adjustable 4 Use and Operation Instruction 10 2 Parameter list Meaning 21...

Страница 25: ...4 Use and Operation Instruction 4 11 Main board 22...

Страница 26: ...23 4 Use and Operation Instruction Main board of the input and output interface instructions below Number Sign Meaning 22 23 Color line controller communication...

Страница 27: ...ge Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed Work procedure Work shal...

Страница 28: ...times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to instal...

Страница 29: ...only with parts specified by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak Cabling Check that cabling will not be subject to wear corrosion exces...

Страница 30: ...igerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holdin...

Страница 31: ...e in accordance with manufacturer s instructions h Do not overfill cylinders No more than 80 volume liquid charge i Do not exceed the maximum working pressure of the cylinder even temporarily j When t...

Страница 32: ...0A 30mA less than 0 1 sec 186 224A 2 95mm2 95mm2 280A 30mA less than 0 1 sec 2 Three phase unit Nameplate maximum current Phase line Earth line MCB Creepage protector Signal line No more than 10A 3 1...

Страница 33: ...0 3 0 5 0 8 1 1 3 1 5 1 8 2 2 3 Temperature R410A 51 3 20 9 4 11 19 24 31 35 39 Temperature R32 52 5 20 9 3 5 10 18 23 29 5 33 3 38 7 Pressure MPa 2 5 2 8 3 3 3 3 5 3 8 4 4 5 5 5 5 Temperature R410A 4...

Страница 34: ...Note...

Страница 35: ...Note...