![fluid-o-tech TMFE2 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/fluid-o-tech/tmfe2/tmfe2_instruction-manual_2308824008.webp)
N
ote
:
PWM frequency signal (100 to 10000 Hz) with amplitude 5V (tOFF = 0V tON = 5V), 10% to 95% duty cycles range. This signal is
interpreted as a real Analog Input (Voltage). Differences in terms of amplitude tON and, in value tOFF different from 0V, modify speed value.
N
ote
:
Insertion tool is Tyco Electronics P/N 59803-1
FAULT SIGNAL
The TMFR/TSFR driver has a fault signal in OR function which
includes the alarms (Autoresettable and Permanent):
1
- Over-voltage;
2
- Under-voltage;
3
- Over-temperature (controller);
4
- Start-up;
5
- Rotor blocked;
6
– Module Fault (hardware)
7
- Over-load power;
8
- Over-current limit (50% more than the over-load power)
In the picture below there is the diagram with the electronic
characteristic of the Fault Signal. It is active when low (0V). When
the TMFR/TSFR unit runs correctly the FAULT signal is high (5V).
From µProcessor
R
2
1
JP4
+ 5 VField
FAULT
0V Field
6
From µProcessor
R
2
1
JP4
+ 5 VField
FAULT
0V Field
6