MANUAL – TMFE2 en – 02/2020 Ed.

Fluid-o-Tech reserves the right to alter the specifications indicated in this catalogue at any time and without prior notice.

STANDARD MAINTENANCE 

The Fluid-o-Tech TMFR/TSFR series units maintenance and 
replacement of parts subject to wear have to be done by a qualified 
technician. Periodic cleaning of the circuit and filters is advisable in 
order to avoid cavitation and wear of the internal components.

WARRANTY

Every new pump manufactured by Fluid-o-Tech is guaranteed to be 
free of defects in workmanship and material when leaving the factory 
for a period of 18 months from the production date stamped on the 
pump’s housing, plus a period of 6 months to cover the warehouse 
and transit time, or for a period of maximum 24 months from the 
purchasing date to the product use. In no event shall this period 
exceed 24 months from date of original invoice. 
Fluid-o-Tech will repair or replace at its judgement part or all of the 
product not conforming to this warranty. 
Fluid-o-Tech’s responsibility under this warranty is limited to the 
repair or replacement of defective equipment returned to us on a 
D.D.P. basis, providing that our analysis discloses that such part or 
parts were defective at the time of sale. 

The warranty is not recognized if: 
•  The directions on how to handle, install or operate the unit are 

disregarded. 

•  The unit has been disassembled or modified by anyone other 

than a Fluid-o-Tech (or authorized by Fluid-o-Tech) engineer or 
repaired with non-original components. 

•  The unit operated dry or in cavitation (throttled/undersized inlet or 

filter). 

•  Solid extraneous particles are found in the pump. 
•  Evident signs of operating pressure higher than 16 bar (high 

pressure may compromise the integrity of the internal parts of the 
pump and cause leaking) are found. 

•  The unit has been utilized for an application for which it was not 

intended to be used where the operating conditions and/or the 
pumped fluids were incompatible with the pump itself and such 
application has not been specifically approved by Fluid-o-Tech. 

•  In case of pumps equipped with relief valve, the operating 

pressure have to be less than 3 bar below the relief valve 
pressure setting. In this case the internal parts get hot, scale 
develops and the hydraulic performances degrades.

Fluid-o-Tech Int’l Inc.

161 Atwater St., 

Plantsville CT (USA) 06479

Tel. +1 (860) 276 9270
Fax +1 (860) 620 0193

[email protected]

Fluid-o-Tech Asia (Shanghai) Co., Ltd.

2/F, Factory building 6 (1), No. 258, Zhijiang Road,

Fengxian District, Shanghai City, Z.P.: 201499 China

Tel. +86 (021) 67100 838
Fax +86 (021) 67100 605

[email protected]

Fluid-o-Tech srl 

Via Leonardo da Vinci, 40

20094 Corsico, Milano, Italy

Tel. +39 02 9995 01

Fax +39 02 9995 0999

[email protected]

Fluid-o-Tech Int’l Inc. Japan

2nd Floor, 4-3-8, Espoir Todoroki, 

Todoroki, Setagaya, Tokyo 158-0082

Tel. +81 (0) (3) 6432 1812
Fax +81 (0) (3) 6432 1813

[email protected]

Содержание TMFE2

Страница 1: ...amage are not marked by a warning triangle The warnings appear in decreasing order of risk as given below Danger Indicates that death or serious injury will result if proper precautions are not taken Warning Indicates that death or serious injury may result if proper precautions are not taken Caution With a safety alert signal indicates that minor personal injury can result if proper precautions a...

Страница 2: ...s must be taken into account All work should be undertaken with the system in a no voltage condition If this is not observed this can result in injury Warning The capacitors mounted in the unit have dangerously high voltage For this reason once the power cord has been disconnected it is necessary to wait three 3 minutes minimum before any service on the device ESDS information and instructions Ele...

Страница 3: ...tamination of the cooling system in order to maintain proper cooling efficiency Supply system Switches contactors fuses Filter MicroProcessor Power module Pump Motor Sensoriess feed back Cable Choke Cable Filter optional Closed loop control Digital Analog Optional MODEL Input Inverter Nominal Out motor Motor Weight Standard Vac KW input current power Kg current A A FEXXEXXX 230V 10 0 25 1 8 0 9 Sa...

Страница 4: ...ose proximity to the inverter storage temperature 20 C to 60 C Environment conditions ventilation natural circulation humidity from 20 to 90 without condensation altitude of installation max 2000 m u s l derating for higher altitudes protection IP 20 Type External connections Digital opto coupled LED orange Indication of Supply permanent Alarms blink Alerts Is located in the center of the main boa...

Страница 5: ...eve max Conductor cross section stranded min 0 2 mm 1 5 mm Conductor cross section stranded max 2 5 mm Conductor cross section stranded with ferrule with plastic sleeve min Conductor cross section stranded with ferrule 0 25 mm Without plastic sleeve min Conductor cross section stranded with ferrule with plastic sleeve max 1 5 mm Conductor cross section AWG kcmil min 24 Conductor cross section AWG ...

Страница 6: ...C NC NC 5 to 24 V polarity can be reversed 0 V polarity can be reversed NC NC SERVICE CONNECTOR TYCO 3 643814 7 OR EQUIVALENT 1 2 3 4 5 6 7 MODE OPTO DIGITAL EXTERNAL DIP MOTOR OFF ON 4 2 1 3 6 5 MOTOR ON DIP SWITCH SETTINGS see previous table 0V 0 5 to 24 V 1 PIN 3 DIP STATUS SERVICE Connector 0V 0 0V 0 PIN 4 SERVICE Connector FUNCTION MODE DIGITAL OPTO ON OFF 7 6 5 4 3 2 1 NC NC NC 5 to 24 V pol...

Страница 7: ...STATUS ON 4 2 7 6 5 4 3 2 0 Vs 0 Vs A I 4 20 mA 0 Vs ON 5 V FAULT OUT Active low 1 3 6 5 DIP STATUS ON 4 2 7 6 5 4 3 2 1 NC 0 Vs A I PWM 5 to 95 TTL signal 0 Vs ON 5 V FAULT OUT Active low 5 Vs SERVICE CONNECTOR TYCO 3 643814 7 OR EQUIVALENT MODE ANALOG IN PWM COMMAND 100 10 000 Hz 1 3 6 5 TATUS 4 7 6 5 4 3 2 1 NC 0 Vs A I 0 5 V 0 Vs ON 5 V FAULT OUT Active low 5 Vs SERVICE CONNECTOR TYCO 3 643814...

Страница 8: ...rature controller 4 Start up 5 Rotor blocked 6 Module Fault hardware 7 Over load power 8 Over current limit 50 more than the over load power In the picture below there is the diagram with the electronic characteristic of the Fault Signal It is active when low 0V When the TMFR TSFR unit runs correctly the FAULT signal is high 5V From µProcessor R 2 1 JP4 5 VField FAULT 0V Field 6 From µProcessor R ...

Страница 9: ... over load power semi permanent alarm mode ELECTRIC INSTALLATION The power connection wires must be of appropriate section in proportion to the current absorbed in the specific application The cable shield must be connected to the ground both on the inverter and on the motor side The power cables must be separated from the control cables it is forbidden passing them in the same raceway It is impor...

Страница 10: ......

Страница 11: ...ncy 50 60Hz OUTPUT RATING Vn 180 Vac 3phase P N FEE2AWR1 99260905 02 I in 5 4 A rms In 1 89A rms W in 375 W 4 3110 in 4 7243 in 2 1692 in 4 2795 in Ø 23 82 5 3 25 in 36 5 57 2 24 in 114 4 49 in 38 1 5 in 90 3 54 in 125 4 92 in X X 4x Ø11 2 x 3 8 NPT 2 x 3 8 GAS TO CONTROLLER CARD BY CONNECTION CABLE X X 125 4 92 in 37 1 46 in 65 2 56 in Ø 0 91 in 1 44 in Ø 0 43 in ...

Страница 12: ...garded The unit has been disassembled or modified by anyone other than a Fluid o Tech or authorized by Fluid o Tech engineer or repaired with non original components The unit operated dry or in cavitation throttled undersized inlet or filter Solid extraneous particles are found in the pump Evident signs of operating pressure higher than 16 bar high pressure may compromise the integrity of the inte...

Отзывы: