SEM-100SS User Instructions

1. Introduction and safety

1.1 General

 These instructions must always be kept close to the 

product’s operating location or directly with the product.

Flowserve products are designed, developed and manufactured with 
state-of-the-art technologies in modern facilities. The unit is produced 
with great care and commitment to continuous quality control, utilizing 
sophisticated quality techniques and safety requirements.

Flowserve is committed to continuous quality improvement and 
being at service for any further information about the product in its 
installation and operation or about its support products, repair and 
diagnostic services.

These instructions are intended to facilitate familiarization with the 
product and its permitted use. Operating the product in compliance 
with these instructions is important to help ensure reliability in service 
and avoid risks. The instructions may not take into account local 
regulations; ensure such regulations are observed by all, including 
those installing the product. Always coordinate repair activity with 
operations personnel, and follow all plant safety requirements and 
applicable safety and health laws and regulations.

 

These instructions must be read prior to installing, operating, using 

and maintaining the equipment in any region worldwide. The equipment 
must not be put into service until all the conditions relating to safety 
noted in the instructions have been met.

Содержание SEM-100SS

Страница 1: ...Experience In Motion SEM 100SS Electronic Flow Meter PUIOM000649 00 ENGLISH REV 07 2022 INSTALLATION OPERATION MAINTENANCE...

Страница 2: ...2 2 Storage 6 2 3 Recycling at end of product life 6 3 Description 7 3 1 General product description 7 3 2 Operating parameters 8 3 3 Available equipment and accessories 8 3 4 Materials of constructi...

Страница 3: ...ration or about its support products repair and diagnostic services These instructions are intended to facilitate familiarization with the product and its permitted use Operating the product in compli...

Страница 4: ...the products to help ensure their continued product quality and performance in use As Flowserve cannot test parts and accessories sourced from other vendors the incorrect incorporation of such parts...

Страница 5: ...ce of an instruction would cause hazards The specific safety markings are This symbol indicates safety instructions where non compliance would affect personal safety and could result in loss of life 1...

Страница 6: ...ipment Each product has a unique serial number Check that this number corresponds with that advised and always quote this number in correspondence as well as when ordering spare parts or further acces...

Страница 7: ...screen with back light large positive touch buttons and simple one touch operation making the meters easy to read and easy to use in both high light and low light settings The SEM 100SS flow meter is...

Страница 8: ...res up to 6 9 bar 100 psi 3 3 Available equipment and accessories The SEM 100 and SEM 100FT electronic flow meters are available individually or in packages with the CT6 chemical transfer pump in mult...

Страница 9: ...mber Polypropylene Sulfide PPS Stainless Steel O rings Viton Electronic Housing Nylon Screws Stainless Steel Note Ensure chemical compatibility between liquid metered and the meter s wetted parts befo...

Страница 10: ...direction through the SEM 100SS flow meter Thread the meter inlet into the female discharge port of the pump or line Using an elbow or coupling screw the discharge hose onto the other port of the mete...

Страница 11: ...r into the three calibration modes starting with CAL 1 4 3 1 Calibration The SEM 100SS Flow Meter has three calibration options CAL 1 CAL 2 and CAL 3 The flow meter can be calibrated in any unit desir...

Страница 12: ...lay will blink as fluid is being pumped 5 Press CAL 1 to complete the calibration process Note The display will return to the Current Total screen and read the previous total CAL 2 Calibration 1 Press...

Страница 13: ...on If Err is displayed no calibration change has taken place CAL 3 Calibration 1 Press CAL 1 to enter calibration mode 2 Press CAL 3 The current CAL 3 number will show 3 Press the UP and DOWN arrow ke...

Страница 14: ...Total units pumped will be displayed as long as TOTAL 2 is pressed Note TOTAL 2 cannot be reset to zero TO DISPLAY FLOW RATE With meter on press and hold the ON button for 2 seconds The display will r...

Страница 15: ...Open valve to relieve system pressure and do not pressurize the system during this procedure 5 1 1 Battery removal To replace battery remove the 8 screws DD6P 43A that hold the electronic assembly to...

Страница 16: ...inuing Remove the 8 screws DD6P 46A to remove electronic assembly S10 11B COMPLETE Remove the 4 screws SFM10000 19 that secure the meter plate SFM10000 14A to the fluid housing SFM10000 13A Remove the...

Страница 17: ...19 SS Screw Short 1 SFM10000 14A Meter Plate 8 NUT 02 10 24 Lock Nut 1 SFM10000 10B Magnet Holder 1 SFM10000 18 Viton O Ring 2 SFM10000 06 Screws 1 SFM10000 05 Mounting Bracket 1 SFM10000 07 Washer 1...

Страница 18: ...022 SEM 100SS User Instructions S10 11 COMPLETE SFM10000 19 SFM10000 07 SFM10000 08 SFM10000 02 SFM10000 01 SFM10000 17 STM10000 20 SFM10000 13A SFM10000 03A SFM10000 05 SFM10000 06 SFM10000 10B SFM10...

Страница 19: ...erating at a different rate Calibrating with a different fluid than what is being pumped Problem Meter flashes ERR at the end of calibration Solution Check for the following Meter electronics are not...

Страница 20: ...through the meter or the meter will not register flow Solution Foreign material is in the metering cartridge and is obstructing flow or preventing the nutating disk from moving freely Remove the meter...

Страница 21: ...MERCHANTABILITY OR FITNESS FOR PURPOSE SHALL APPLY Flowserve is not responsible for repairs or alterations made by others without manual written agreement between the Company and Buyer The Company doe...

Страница 22: ...lowserve products The purchaser user should read and understand the Installation Instructions included with the product and train its employees and contractors in the safe use of Flowserve products in...

Отзывы: