Logix
®
Digital Positioners FCD LGENIM0110-0 05/16
flowserve.com
11
16
SPECIFICATIONS
16.1 Input Signal
Table 1: Input Signal
Positioner Alone
or with
Multi-Function Card
Power Supply
Two-wire, 4-20 mA
10.0 VDC plus line losses.
Input Signal Range
4 - 20 mA (HART)
Compliance Voltage
10.0 VDC
@ 20 mA
Effective Resistance
500 Ω @ 20 mA Typical
Minimum Required
Operating Current
3.9 mA
Maximum Shut-down
Current
3.6 mA
Power Interruption
Time Limit
After power has been applied for at least 10
seconds, a 60 ms power interruption will not
cause the positioner to reset.
Power-up time
Time from application of power to begin
controlling valve < 1.0 second.
Communications
HART protocol
16.2 Pneumatic Output
Table 2: Pneumatic Output
Output Pressure
Range
0 to 100% of air supply pressure.
Output Air Capacity
14.3 Nm³/h @ 1.5 bar
(8.44 SCFM @ 22 PSI)
30.6 Nm³/h @ 4.1 bar
(18.0 SCFM @ 60 PSI)
Primary Output Ports
(Port is pressurized in
energized state. Port
is exhausted upon loss
of power.)
Double Acting Relay
– Port 1
16.3 Air Supply
Table 3: Air Supply
Minimum Input
Pressure
2.1 Bar (30 PSI)
Maximum Input
Pressure
10.3 Bar (150 PSI)
Air Supply Quality
The air supply must be free from moisture,
oil and dust by conforming to the ISA
7.0.01 standard. (A dew point at least 18
degrees Fahrenheit below ambient
temperature, particle size below five
microns
—one micron recommended—and
oil content not to exceed one part per
million).
Operating Humidity
0 - 100% non-condensing
Acceptable Supply
Gasses
Air, sweet natural gas, nitrogen and CO2
are acceptable supply gasses.
Sour natural gas is not acceptable.
For Type nA and Type tb installation only
air or inert gas may be connected to the air
supply inlet.
Air Consumption
0.5 Nm³/h @ 4 bar
(0.3 SCFM @ 60 PSI)
Air Delivery
12 SCFM @ 60 PSI (0.27 Cv)
16.4 Analog Output
– Multi-Function
Card
Table 4: 4 to 20 mA Analog Output Specification
For entity parameters, see section 17 HAZARDOUS AREA
CERTIFICATIONS.
Power Supply Range
10.0 to 40 VDC, (24 VDC Typical)
Current Signal Output
4 to 20 mA
Linearity
1.0% F.S.
Repeatability
0.25% F.S.
Hysteresis
1.0% F.S.
Operating Temperature
-52 to 85°C (-61.6 to 185°F)