MOUNTING ECHOPOD
®
The sensor should always be mounted perpendicular to the liquid surface using the provided Viton
®
mounting
gasket. Make sure that there are no restrictions or obstacles in the path of the acoustic signal. For further
mounting information, please refer to the EchoPod
®
manual and instruction video located at flowline.com.
Mounting with a Tank Adapter
Select a tank adapter fitting, such as the LM52-2890.
Mounting in Riser
As installations with tall, narrow risers can impede the
acoustic signal. 2" diameter risers should be no taller than 4".
Larger diameter risers should be no taller than 12".
Mounting in Side Mount Bracket
Use Flowline's LM50-1001 side mount bracket.
LM50-1001 Shown
Note:
The Side Mount Bracket (LM50 series) is not designed for use with stand pipes or as a method to
secure stand pipes. There are too few threads to properly hold the sensor and the stand pipe.