Boost Pump Control
When the pump is first installed or high-pressure tubing
is replaced, you must purge the system by sending pres-
surized water through it. Touch the
[I]
button while the
pump is off to energize the boost pump and purge the
system.
Note
: The operator must
block
the bleed-down to
drain so the water can flow through the high-pressure
tubing, then open the bleed-down to drain when purging
is finished so the pump can operate normally.
Turn off the purge system by touching the
[O]
button,
by cycling power to the system, or by starting the pump.