![Flow 94i-D Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/flow/94i-d/94i-d_manual_2307762027.webp)
Configuration screens
The Configuration screens display information about the pump’s current configuration. You can also change the con-
figuration of the pump’s UHP offset and pressure points on these screens.
Configuration Screen 1
The indicators on
Configuration Screen 1
show how the
pump is running.
•
Set
Pump Mode
to “1” for standalone operation.
•
Pump Units
are “0” for °F/Psi and “1” for °C/Bar.
Note: do not change this while the pump is running!
•
Pump Size
is “0” for 50HpA, “1” for 100Hp, and
“2” for 50HpB (see the
Defaults
screen for a defini-
tion of these pumps)
•
Ramp Time
can range from 20 to 100
(2–10 seconds)
•
Datalog Interval
time can range from 50 to 3000
(5–300 seconds) between samples. The shorter the
interval, the higher the resolution of the data, but
the shorter the time span of the total data set.
•
Boost On Delay
can range from 10 to 25
•
Boost Off Delay
can range from 10 to 35
•
Motor 2 On Delay
can range from 10 to 30
To change a value, touch that number on the screen. A
keypad will appear; enter the desired value, then touch
the
ENTER
button to accept the value.
Navigation
•
Touch the
Setpoints
button to continue to
Configuration Screen 2
•
Touch the
Defaults
button to continue to the
Defaults
screen
Configuration Screen 2
The indicators on
Configuration Screen 2
shows how
the pump is configured.
•
Oil Level Delay
can range from 10 to 50
•
Aux Feedback Delay
can range from 60 to 600
•
CV Temperature
can range from 40–80°F (25–45°C)
above inlet water temperature
•
Water Pressure Delay
can range from 50 to 600
•
Overpressure Delay
can range from 300 to 6000
•
Overpressure Value
can range from
93500–96500 psi (6447–6657 Bar)
Navigation
•
Touch the
Setpoints
button to continue to
Configu-
ration Screen 3
© Flow International Corporation
M-390 | 27
CHAPTER 3
Operating the 87K Standalone Pump
Содержание 94i-D
Страница 1: ...HYPERJET 94i S 94i D M 390 REV C APRIL 2010 ...
Страница 6: ...Notes 6 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...
Страница 20: ...Notes 20 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...
Страница 30: ...Notes 30 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...
Страница 40: ...Notes 40 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...
Страница 75: ...CHAPTER 7 Customer Support MS 2266 Customer Support Flow International Corporation M 390 75 ...
Страница 76: ...Notes 76 M 390 Flow International Corporation HYPERJET 94i S AND 94i D PUMPS ...