13 Instruction Manual
2.7.2 V-method Installation
V-method installation is the most widely mode for daily measurement with pipe inner
diameters ranging from 15 mm to 400 mm. It is also called reflective mode.
2.7.3 Z-method Installation
Z-method is commonly used when the pipe diameter is above 200mm.