Flow Controller Systems FCS KA1 Скачать руководство пользователя страница 12

 

           

 

   

 

    KA1

- 9 - 

 

7.

 

Main Function and Feature 

Ø

 

2.4 inch true color LCD display. 

Ø

 

Ultra-quiet drive settings, accurate control, low vibration and noise. 

Ø

 

Mechanical keypad and menu interface are convenient for users setting parameters. 

Ø

 

Easy to operate speed regulation by digital knob. 

Ø

 

Various external control functions, there are 3 analog signal speed regulations: 0-5V, 0-10V, 4-20mA. 

Ø

 

Power down memory function, save the data in time. 

Ø

 

It is suitable for complex working environment with super anti-interference and wide voltage design 

Ø

 

Fast filling function, which can not only clean the tubing, but also fill the tubing with liquid. 

 

8.

 

Dimension Drawing 

Unit: (mm) 

 

 

9.

 

Maintenance 

Ø

 

Check the running status of machine before starting it, normal operation can be put into use.

 

Ø

 

Check for leakage, and correct fault which can be appeared.

 

Ø

 

Clean liquid overflowed from the pump in time.

 

Ø

 

Please turn off the power supply and unplug the power socket (Hold the socket instead of power cord) when liquid splashed on 

pump. Check whether liquid flows into the machine, if it does, please contact the manufacture.

 

Ø

 

The foot pedal switch and other external control plugs must be connected or disconnected in the power-off status to prevent the 

external control interface from being burned. 

Ø

 

The user’s power socket must have ground wire, and have reliable grounding. 

Ø

 

This product has no waterproof measures. Please take protective measures when using in water environment. 

Ø

 

This product does not have special certification such as medical certification. When it needs to be used in special fields such as 

medical and military, please self-certify. 

Ø

 

If the pump does not use for a long time, please clean it and keep it in dry and ventilated environment. 

Ø

 

The company shall not bear the direct and indirect losses caused by the malfunction or improper operation of this product. 

 

10.

 

Warranty and After-sales Service 

We support 3 years warranty for the pumps, subject to the exceptions below. Our company shall not be liable for any loss, damage, or 

expense directly or indirectly related to or arising out of the use of its products. This warranty does not obligate our company to bear 

any costs of removal, installation, transportation, or other charges which may arise in connection with a warranty claim. 

If the pump fails during the warranty period, after confirmation by our technical department, we will provide spare parts free of charge. 

Customers will need to bear the shipping cost. 

Exceptions: 

Содержание FCS KA1

Страница 1: ...FCS KA1 Compact Peristaltic Pump Operation Manual 0 1 2 3456 1 7 7 8 9 88 1 6 A B6 1...

Страница 2: ...f the power cord or plug had wear and other damage please disconnect the plug Hold the plug instead of the wire If following situations happened please turn off the power supply and disconnect the plu...

Страница 3: ...and Interface Instruction 1 3 Operation Panel Instruction 1 4 Operation Interface Structure 2 5 External Control Interface 7 6 Technical Parameters 8 7 Main Function and Feature 9 8 Dimension Drawing...

Страница 4: ...tion KA1 can meet variety of working environment with pure imported keyboard which has 300000 times lives l Start Stop Button Press Start stop button pumps run according to current speed press Start s...

Страница 5: ...n stop status Direction The screen displays when in clockwise displays in counterclockwise Flow speed displays Displays the flow value with the current pump head tubing and speed Parameters Displays a...

Страница 6: ...tart running and start calibration The countdown is displayed at the test time c When in status 1 press Knob button switch to status 2 when in this status rotate Knob button set the test time d After...

Страница 7: ...us 1 and ensure items The product support Modbus communication protocol RTU mode communication interface RS485 Baud rate means Symbol Baud rate Data bits Stop bit Check bit 9600 8 e 1 9600 8 1 Parity...

Страница 8: ...s 1 rotate Knob button the cursor moves up and down to select external control speed signal maximum speed b When in status 1 press Knob button to status 2 c When in status 2 rotate Knob button to sele...

Страница 9: ...signal When the motor speed and analog signal reach the set maximum speed according to the corresponding proportional relationship the analog signal will be increased at this time and the motor speed...

Страница 10: ...p port In pulse mode pin1 is short circuited with pin14 and then disconnect the motor will run do it one more time the motor will stop In level mode pin1 is short circuited with pin14 the motor will r...

Страница 11: ...3 Start motor the relay pull in the motor stop the relay disconnect l The square Port USB interface is shown in the figure below Square Port USB interface equipped with square port data cable can be u...

Страница 12: ...lugs must be connected or disconnected in the power off status to prevent the external control interface from being burned The user s power socket must have ground wire and have reliable grounding Thi...

Страница 13: ...and pumping accessories as consumable items are excluded Electrical surge as a cause of failure is excluded Chemical attack is excluded Improper operation or man made damage as a cause of failure is e...

Отзывы: