This Pedestal Sump Pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-
type power cord. Sleeve bearings on motor shaft never
need lubrication. Automatic reset thermal protection.

NOTICE

:

This unit is not designed for applications

involving salt water or brine! Use with salt water or
brine will void warranty.

SPECIFICATIONS

Power supply required ........................115V, 60 HZ.
Horsepower ........................................................1/2
Motor duty .............................................Intermittent
Liquid Temp. Range ...............32°F to 70°F(0°-21°C)
Individual Branch Circuit Required 
GFCI Class A ..............................................15 Amps
Motor full load (maximum) .......................7.3 Amps
Discharge: Cast Iron Models...............1-1/2" FNPT

PERFORMANCE

GENERAL SAFETY

Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from func-
tioning normally. To prevent possible water damage
due to flooding, consult your retailer about a sec-
ondary AC sump pump, a DC backup sump pump,
and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for informa-
tion about common sump pump problems and
remedies. For more information, see your retailer or
call Flotec customer service at 1-800-365-6832.
1. Know the pump application, limitations, and

potential hazards.

Risk of explosion

. Do not use in

explosive atmospheres. Pump

water only with this pump. Failure to follow this
warning can result in personal injury and/or prop-
erty damage.

2. Disconnect power before servicing.
3. Release all pressure within system before servic-

ing any component.

4. Drain all water from system before servicing.

Risk of flooding. 

If a flexible dis-

charge hose is used, pump may

move when motor starts. If it  moves far enough
so that switch hits side of sump, switch may stick
and prevent pump from starting.Make sure pump
is secured so it cannot move around in sump.

5. Secure discharge line before starting pump. An

unsecured discharge line will whip, possibly
causing personal injury and/or property damage.

6. Check hoses for weak or worn condition before

each use, making certain all connections are secure.

7.

Inspect sump, pump and system components
monthly. Keep free of debris and foreign
objects. Perform routine maintenance as
required. 

Risk of Fire. 

Do not store or

rest objects on or near motor

or switch linkage. Keep all flammable objects
or liquids away from motor.

8.

Provide means of pressure relief for pumps
whose discharge line can be shut-off or
obstructed.

9.

Personal Safety:

a. Wear safety glasses at all times when work-

ing with pumps.

b. Keep work area clean, uncluttered and

properly lighted – replace all unused tools
and equipment.

c. Keep visitors at a safe distance from work

area.

d. Make workshop child-proof – with padlocks,

master switches, and by removing starter
keys.

10. When wiring an electrically driven pump, fol-

low all electrical and safety codes, as well as
most recent National Electrical Code (NEC) and
Occupational Safety and Health Act (OSHA).

11. This equipment is only for use on 115 volt (sin-

gle phase) and is equipped with an approved 3-
conductor cord and 3-prong, grounding-type
plug.

To reduce risk of electric
shock, be certain that it is

connected to properly grounded, grounding-
type receptacle.
•   

Never connect green (or green and yellow)
wire in cord to a live terminal!

•   Where a 2-prong wall receptacle is encoun-

tered, it must be replaced with properly
grounded 3-prong receptacle installed in
accordance with the National Electrical
Code and local codes and ordinances.

12.  All wiring should be performed by a qualified

electrician.

13. Make certain that power source conforms to

requirements of your equipment.

14. Protect electrical cord from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking
cord. Replace or repair damaged or worn cords
immediately.

15. Do not touch an operating motor. Modern

motors are designed to operate at high temper-
atures.

16. Do not handle pump or pump motor with wet

hands or when standing on wet or damp sur-
face, or in water.

Risk of Shock.

If your basement

has water or moisture on floor, do

not walk on wet area until all power has been
turned off. If shut-off box is in basement, call elec-
tric company to shut-off service to house, or call
local fire department for instructions. Remove pump
and repair or replace. Failure to follow this warning
can result in fatal electrical shock.

GPH (LPH) AT TOTAL FEET (M)

5 Ft.

10 Ft.

15 Ft.

20 Ft.

(1.52)

(3.05)

(4.57)

(6.09)

4,200

3,830

2,720

950

(15,897L)

(14,497L)

(10,295L)

(3,596L)

Содержание FPPSS5000

Страница 1: ...s For further operating installation or maintenance assistance Call 1 800 365 6832 English Pages 2 6 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installat...

Страница 2: ...tore Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pum...

Страница 3: ...n condition before each use making certain all connections are secure 7 Inspect sump pump and system components monthly Keep free of debris and foreign objects Perform routine maintenance as required...

Страница 4: ...h with top of rod 10 Position lower rod stop to within 8 20cm of switch lever arm With lower rod stop in this position pump will automatically cycle at approximately 2 1 2 6cm off and 10 12 25 30cm on...

Страница 5: ...ctrical malfunction Check power cord automatic switch and motor Replace faulty parts as needed Motor runs but Inlet clogged Check inlet and clean if needed pump will not Discharge line plugged Clear d...

Страница 6: ...h 1 2 Set Screw 4 U30 946PH 3 Shaft 1 RP0005257 4 Support Column 1 S15 37SS 5 Volute 1 S1 34B 6 Impeller 1 S5 13P 7 Base Plate 1 PS4 17P 8 Screw base plate 8 U30 571BT 9 Float Rod Guide 1 RP0005249 10...

Страница 7: ...s pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe de...

Страница 8: ...se d place pas dans le puisard 5 Caler la canalisation de refoulement avant de d marrer la pompe Une canalisation non cal e peut donner des coups de fouet qui risquent de provoquer des blessures corpo...

Страница 9: ...orsque le dispositif d arr t inf rieur se trouve dans cette position le cycle de la pompe se r gle automatiquement 6 cm 2 1 2 po pour l arr t et 25 cm 10 12 po pour la marche Pour un cycle plus rapide...

Страница 10: ...ique interrupteur automatique lectrique et moteur Remplacer les pi ces d fectueuses si n cessaire Le moteur Cr pine bouch e V rifier la cr pine et la nettoyer si n cessaire tourne mais Canalisation de...

Страница 11: ...base 1 PS4 17P 8 Vis plaque de base 8 U30 571BT 9 Guide de tige du flotteur 1 RP0005249 10 Vis colonne volute non repr sent e 1 U30 946PH 11 Flotteur 1 FT0013 63 12 Tige du flotteur 1 RP005168S 13 Dis...

Страница 12: ...tamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado Use guantes...

Страница 13: ...descarga est suelta puede latiguear ocasionando posibles da os personales y o materiales 6 Inspeccione las mangueras antes de usar la bom ba para asegurarse de que est n en buen estado y verifique que...

Страница 14: ...pe inferior de la varilla a unas 8 20 cm del brazo de la palanca del interruptor Con el tope inferior de la varilla en esta posici n la bomba tendr ciclos autom ticos de aproximadamente 2 1 2 6 cm afu...

Страница 15: ...ico y el motor Reemplace las partes defectuosas seg n sea necesario El motor Entrada tapada Inspeccione la entrada y l mpiela si fuera necesario funciona pero Tuber a de descarga Limpie la tuber a de...

Страница 16: ...4 Columna de Soporte 1 S15 37SS 5 Espiral Caja de la Bomba 1 S1 34B 6 Impulsor 1 S5 13P 7 Placa de asiento 1 PS4 17P 8 Tornillo placa de asiento 8 U30 571BT 9 Gu a de la Varilla del Flotador 1 RP00052...

Отзывы: