background image

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

Installation

5

TESTING FOR BLADDER 

LEAKAGE

Step 1. Disconnect power to pump.
Step 2. Drain water from tank bladder by opening

faucet closest to tank.

Step 3. Remove valve cap and release all pressure

by depressing valve core. When air stops
coming from valve, remove valve core to
release remaining pressure.

Step 4. Disconnect piping from elbow on tank

cover flange.

Step 5. Carefully turn tank upside down or lay on

its side.

Retained water in tank may

cause sudden weight shift when lowering. Support
tank so it cannot fall when being lowered or
inverted.
Step 6. If bladder leaks, water will run out of valve.

If so, replace bladder.

Step 7. If replacing bladder, be sure air and water

pressures are relieved before removing
cover flange. When reassembling cover
flange, do not tighten nuts or mounting
studs more than 85 in-lbs. (9.6 Nm).

NOTICE: When using metal pipe with plastic fit-
tings use only Teflon tape or Plasto-Joint Stik

1

on

male threads.

NOTICE: Most standard tanks have separate inlet
and outlet ports. Pre-charge tanks have one port
serving both functions. When replacing standard
tank with a pre-charge tank, run pipe from pump
into a tee as shown. 2nd leg of tee goes to tank
elbow; 3rd leg goes to existing service.

To service

Pressure

Relief Valve

Pressure

Gauge

Pressure

Switch

From Well

160 0893

Figure 5: Typical installation with vertical
pre-charge tank and submersible well
pumps

Maximum

Equivalent

Tank

Tank

Tank

Catalog

Capacity

to Standard

Diameter

Height 

Discharge

Number

US Gals (L)

Tank US Gals (L)

(mm)

(mm)

Tapping

FP7100-04

6 (23)

15 (57)

12" (305)

*16-1/2" (419)

3/4"

FP7100H-04

6 (23)

15 (57)

12" (305)

*16-1/2" (419) 

3/4"

FP7110T-04

19 (72)

42 (159)

16" (406)

30-1/8" (765)

1"

FP7110TH-04

19 (72)

42 (159)

16" (406)

*24-5/8" (625) 

1"

FP7110-04

19 (72)

42 (159)

20" (508)

22-3/4" (578)

1"

FP7120-04

35 (132)

82 (310)

20" (508)

36-1/4" (921)

1"

FP7125-04

50 (189)

120 (454)

24" (610)

34-3/4" (883)

1-1/4"

FP7130-04

85 (322)

220 (833)

24" (610)

54" (1372)

1-1/4"

Drawdown - Gals (L)

Catalog

20-40 PSI

30-50 PSI

40-60 PSI

Number

(138-276kPa)

(207-345kPa)

(276-414kPa)

FP7100-04

2.2 (8.3)

1.8 (6.8)

1.6 (6.1)

FP7100H-04

2.2 (8.3)

1.8 (6.8)

1.6 (6.1)

FP7110T-04

6.9 (26.1)

5.8 (22)

5.0 (18.9)

FP7110TH-04

6.9 (26.1)

5.8 (22)

5.0 (18.9)

FP7110-04

6.9 (26.1)

5.8 (22)

5.0 (18.9)

FP7120-04

12.7 (48.1)

10.7 (40.5)

9.3 (35.2)

FP7125-04

18.3 (69.3)

15.5 (58.7)

13.4 (50.7)

FP7130-04

30.0 (113.6)

26.0 (98.4)

22.0 (83.3)

* Length overall; this model is a horizontal tank.

Product Information – Pre-Charged Tanks

Содержание FP7100H-04

Страница 1: ...04 FP7100H 04 FP7110 04 FP7110T 04 FP7110TH 04 FP7120 04 FP7125 04 FP7130 04 Models FP7125 04 and FP7130 04 do not have the pump mounting bracket Water is Our Business Installation Operation Parts For...

Страница 2: ...eptions to the Twelve 12 Month Warranty Ninety 90 Day Warranty If within ninety 90 days from original consumer purchase any Drill Pump or In Line Water Filter Cartridge shall prove to be defective it...

Страница 3: ...capacity is the actual physical volume of the sheet metal that makes up the tank OPERATING CYCLE FIGURE 2 Step 1 Tank nearly empty air expands filling area above bladder Figure A Step 2 Water enters...

Страница 4: ...e per cycle If this occurs adjust pre charge pressure according to Chart 1 page 3 Flush all air out of piping system and water reser voir portion of pre charged tank Required on new installations pump...

Страница 5: ...functions When replacing standard tank with a pre charge tank run pipe from pump into a tee as shown 2nd leg of tee goes to tank elbow 3rd leg goes to existing service To service Pressure Relief Valve...

Страница 6: ...RTL Model FP7100 04 Model FP7100H 04 Key Part No No Description Used FP7100H 04 FP7100 04 1 Bladder Vinyl 1 U20 7 U20 7 2 Cover Flange 1 U31 442P U31 442P 3 Flanged Nut 5 16 18 Hex 6 U36 202BT U36 20...

Страница 7: ...31 446P U31 446P U31 446P 3 Flanged Nut 5 16 18 Hex 6 U36 202BT U36 202BT U36 202BT 4 Air Valve with Cap 1 U212 160 U212 160 U212 160 Key Part No No Description Used FP7120 04 FP7125 04 FP7130 04 1 Bl...