20
20
ENGLISH
9. If the filler hose is on the pipeline, con-
tinue to fill the pipe and pump until
water overflows also from this second
hole.
10. Insert the second filler cap.
11. Start up the pump and wait for the
liquid to be pumped. The pump can
run for 5 minutes to attempt to acti-
vate liquid suction. If the pump does
not generate pressure and flow rate,
repeat steps 1 to 11.
The check valve in Figure 3 serves to pre-
vent emptying of the pump under a siphon
effect at the time of shutdown, so that
liquid stays in the pump body for subse-
quent start-up.
If there is no foot valve or check
valve on the suction port, filling
must be repeated before each
start-up.
If the pump has difficulty in in-
creasing pressure, repeat opera-
tions 1 to 11. If, after several at-
tempts, the pump does not operate
correctly, see the fault section "quick
troubleshooting guide"
Operation with frequency con-
verter
If the pump is connected to a frequen-
cy converter during start-up, the pump
should run at maximum speed. If the
pump does not prime within 5 minutes,
stop the motor and repeat steps 1 to 11.
Pump start-up
Use the electric pump according
to the performance specifica-
tions as stated on the data plate.
Always avoid operation of the
pump with the upline shutoff
valve closed (suction side). Dry running of
the pump can lead to overhearing and
damage to the pump itself.
Never run the pump with the
shutoff valve downline (delivery
side) completely closed. In this
case, the water in the system reaches
very high temperatures, with the risk of
damage to equipment and scalding in the
event of escape of the liquid. In this situa-
tion, turn off the pump and leave the sys-
tem to cool.
Never use the pump in the event
of cavitation, as this can cause
damage to the hydraulic compo-
nents.
Pressure on the downline side of
the pump (delivery side) must
never exceed the maximum op-
erating pressure PN as indicated on the
pump data plate (see “Application Limits”
Figure 5). Pressure downline of the pump
is obtained from the sum of the pressure
delivered and the pressure on the suction
side (gravity for installations with negative
suction head, aqueducts, or water system
where admissible or required).
1. Check that the shutoff valves downline
of the pump (delivery side) and upline
of the pump are in the open position.
2. Start the pump.
3. If the pump does not start up correctly,
on reaching the operating conditions in
a short time, the pump shuts down.
4. In this case repeat the “Pump priming”
phase.
LOGIC-SAFE
(Electronic device that protects the elec-
trical pump) models Evo-Multimax 340
Logic Safe, Evo-Multimax 550 Logic Safe
Содержание EVO-MULTIMAX 340 KIT
Страница 2: ...2...
Страница 46: ...46 DEUTSCH...
Страница 165: ...165...
Страница 166: ...166 8...
Страница 167: ...167 RCD 30 mA Evo Multimax ACS 5 C 50 C 40 C 8bar 0 8MPa 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...
Страница 168: ...168 70dB LpA Evo Multimax 340 Logic Safe Evo Mul timax 550 Logic Safe Evo Multimax 840 Evo Multimax 340 Kit A1 50 40 C...
Страница 169: ...169 1 1 2 3 2 3 1 2 3 4 5 3 4m 0 5m 2 3 H1 0 5m 2...
Страница 170: ...170 3 H3 4 2 3 RCD 30mA 4...
Страница 171: ...171 1 1 2 3 4 5 2 3 1 1 2 3 2 4 5 6 7 2 3 8 9 10 11 5 1 11 3...
Страница 172: ...172 1 11 5 1 11 PN 5 1 2 3 4 LOGIC SAFE Evo Multimax 340 Logic Safe Evo Multi max 550 Logic Safe Evo Multimax LOGIC Safe...
Страница 174: ...174 LOGIC SAFE...
Страница 175: ...175 LOGIC SAFE...
Страница 176: ...176...
Страница 188: ...188...
Страница 189: ...189 8...
Страница 190: ...190 RCD 30 A Evo Multimax AC 5 C 50 C 40 C 8 0 8 M a 5 1 2 3 4 5...
Страница 192: ...192 1 1 2 3 2 3 1 2 3 4 5 3...
Страница 193: ...193 4 0 5 2 3 H1 0 5 2 3 2 3 3 4 30 A...
Страница 194: ...194 4 1 1 2 3 4 5 2 3 1 1 2 3 2 4 5 6...
Страница 195: ...195 7 2 3 8 9 10 11 5 1 11 3 1 11 1 11 PN...
Страница 197: ...197 Failure Restart Failure Restart Failu re Restart RESTART...
Страница 198: ...198 LOGIC SAFE LOGIC SAFE...
Страница 199: ...199...
Страница 200: ...200...
Страница 210: ...210 1...
Страница 211: ...211 2...
Страница 215: ...215...
Страница 216: ...PENTAIR INTERNATIONAL S a r l Avenue de Sevelin 18 1004 Lausanne Switzerland...