background image

Installation • Operation 

5

For parts or assistance, call Flotec Customer Service at 1-800-365-6832

High Water Alarm
If the water level remains at ON (short probe 

in the water) for more than 15 seconds, the 

High Water Alarm will sound. It will continue 

to sound until the water level drops below the 

tip of the ON probe or until it is unplugged. 

However, if the water level remains up to the 

ON level, the Alarm will resume sounding as 

soon as the switch is plugged in again. The 

High Water Alarm automatically stops sounding 

when the water level drops below the tip of the 

ON probe.
Remote Alarm Connection
When the High Water Alarm sounds, it also 

closes a normally open (NO) dry contact which 

can be connected to a voice dialer or home 

security system, alerting you to abnormal high 

water conditions. Use low voltage wire for 

the connection. The contact is not sensitive to 

polarity, so it doesn’t matter which wire goes to 

which pole of the contact (see Figure 10).
Replacement and Maintenance

 Risk of electrical shock. Unplug the 

pump before handling it, removing it from the 

sump, or working on it.
To remove the switch, spread the tabs on the top 

of the bracket just far enough to slide the switch 

out between them. Use the wire to push the 

switch forward out of the bracket (see Figure 11).
To replace the switch, push it back between the 

bracket tabs until it is flat against the back of the 

bracket (see Figure 11).
Maintenance: Whenever the pump is removed 

from the pit (be sure to unplug the pump before 

you handle it!), wipe down the three stainless 

steel switch rods with a clean cloth.

Operation

1.  The shaft seal depends on water for 

lubrication. Do not operate the pump unless 

it is submerged in water; running it dry may 

damage the seal.

2.  If the pump overheats, an automatic-reset 

thermal protector cuts off the power and stops 

the motor before it can be damaged. The motor 

will automatically restart when it cools. If the 

protector trips repeatedly, unplug the pump, 

remove it from the sump, and check it for 

the cause of the difficulty. Low voltage, long 

extension cords, clogged impeller, very low lift, 

a plugged or frozen discharge pipe, etc., can 

all cause cycling and overheating.

3.  This pump will not remove all the water in the 

sump. If you are running the pump manually 

and water stops coming out of the discharge, 

the pump has probably run dry. Shut it off 

immediately and check the water level.

Off

On

Ground

Off Probe has 

Long PVC Sleeve

Ground Probe has 

Short Plastic Sleeve

 

Figure 9: IntelliShield probes.

 

 

Figure 11: Switch snaps out of bracket as shown. 
Be careful not to spread the catches too far.

  

  

 

Figure 10: Connect dry contacts to voice dialer 
or home security system. Connect one wire to 
each terminal; polarity doesn’t matter.

Voice dialer or 

home security 

hardware

Содержание E100ELT

Страница 1: ...ges 2 9 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 10 17 Instalaci n Operaci n Piez...

Страница 2: ...he pump before handling or servicing it If your basement floor is wet turn off all power before walking on it If the shut off box is in the basement call your electric company or hydro authority to sh...

Страница 3: ...Be sure the hole is below the waterline and below the check valve 2D To reduce noise and vibration cut the discharge pipe near the pump and fasten a short length of rubber hose 1 7 8 48 mm I D e g rad...

Страница 4: ...ground wire system Do not cut off the round ground pin 7A After you have installed the piping check valve and float switch the pump is ready for operation 7B Check the pump by filling the sump with w...

Страница 5: ...To replace the switch push it back between the bracket tabs until it is flat against the back of the bracket see Figure 11 Maintenance Whenever the pump is removed from the pit be sure to unplug the...

Страница 6: ...y 1 PS17 1560 4 Impeller 1 PS5 35P NOTICE If motor fails replace entire pump See Page 8 for impeller replacement instructions Sump Pit Check Valve Install Vertically Basement Floor Discharge Pipe Lift...

Страница 7: ...nplug the pump remove it from the sump and clean the pump and piping Restricted intake screen Unplug the pump remove it from the sump and clean the intake screen and impeller Pump operates but deliver...

Страница 8: ...with a screwdriver and unscrew the impeller as shown NOTICE The impeller has a left hand thread so it loosens to the right Step 3 Thread the new impeller onto the motor shaft as shown left hand thread...

Страница 9: ...Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump Fo...

Страница 10: ...pompe avant de la manipuler ou de l entretenir Si le plancher du sous sol est humide ne pas marcher dessus tant que le courant n aura pas t coup Si le coffret des disjoncteurs se trouve au sous sol ap...

Страница 11: ...pompe Poser le clapet antiretour au dessus de ce trou et aussi pr s que possible de la pompe S assurer que le trou est plus bas que la ligne d eau et que le clapet antiretour 2D Pour r duire le bruit...

Страница 12: ...e fils de mise la terre Ne jamais couper la broche ronde de mise la terre 7A Apr s avoir branch la tuyauterie le clapet antiretour et l interrupteur flotteur la pompe est pr te fonctionner 7B V rifier...

Страница 13: ...e 11 Pour reposer l interrupteur le pousser entre les attaches du support jusqu ce qu il repose plat contre l arri re du support se reporter la Figure 11 Entretien Lorsque la pompe est sortie du puisa...

Страница 14: ...Sur de grandes longueurs de tuyaux le frottement de l eau circulant dans les tuyaux diminuera le d bit 5 9 Tuyau de refoulement Plancher du sous sol Puisard Refoulement Clapet antiretour installer ver...

Страница 15: ...sale Essuyer l interrupteur l aide d un chiffon propre La pompe d marre et s arr te trop souvent Circulation contre courant de l eau dans les tuyaux Poser un clapet antiretour ou remplacer l ancien In...

Страница 16: ...l impulseur comme illustr AVIS Le filetage de l impulseur gauche il faut donc le tourner droite pour le d visser tape 3 Visser l impulseur neuf sur l arbre du moteur comme il est illustr filetage gauc...

Страница 17: ...mpes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fi...

Страница 18: ...i n o mantenimiento Si el piso de su s tano est mojado desconecte la corriente el ctrica antes de caminar sobre el mismo Si la caja de desconexi n est en el s tano llame a su empresa o autoridad de se...

Страница 19: ...de retenci n por encima de este orificio pero mant ngalo tan cerca de la bomba como sea posible Verifique que el orificio se encuentre debajo de la l nea de agua y por debajo de la v lvula de retenci...

Страница 20: ...haber instalado la tuber a la v lvula de retenci n y el interruptor de flotador la bomba estar lista para funcionar 7B Inspeccione la bomba llenando el sumidero de agua y observando su funcionamiento...

Страница 21: ...Para volver a colocar el interruptor emp jelo hacia atr s entre las leng etas del soporte hasta que haya quedado plano contra la parte posterior del soporte ver la Figura 11 Mantenimiento Siempre que...

Страница 22: ...corre a trav s de la tuber a tambi n reducir el flujo en trayectos largos de tuber a 5 Piso del s tano Levante altura Foso de recogida Tuber a de descarga V lvula de retenci n instalar verticalmente...

Страница 23: ...ario reemplace el impulsor Interruptor sucio Limpie el interruptor con un pa o limpio La bomba se enciende y se detiene con demasiada frecuencia Retroflujo de agua desde la tuber a Instale o reemplace...

Страница 24: ...on un destornillador y destornille el impulsor seg n se ilustra AVISO El impulsor tiene una rosca izquierda de manera que se afloja hacia la derecha Paso 3 Enrosque el nuevo impulsor en el eje del mot...

Страница 25: ...ienda minorista Comun quese con el Departamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: