3

L100235 - Autojet & Multimax Owner’s manual  |  Copyright© Pentair Australia Pty Ltd 2017

Model Data

Model

Motor

(W)

AJP60

600

AJP80

1100

MMP1200

1100

Technical Information

Inlet 

(Suction): 

   

1” BSPF

    

Outlet (Discharge): 

 

 

1” BSPF

  

Water Temperature Range: 

 

1º - 40ºC

IP 

Rating: 

   

IPX4/F

Electrical Supply: 

 

 

230V, 50Hz 

     

single phase 

Maximum Ambient temperature: 

40 ºC

Содержание Autojet60

Страница 1: ...e proceeding with the installation or operation of this product We recommend for additional protection the pump to be supplied from socket outlet protected by a residual current device RCD also known...

Страница 2: ...Autojet Multimax Owner s manual Copyright Pentair Australia Pty Ltd 2017 Table of Contents Page Model Data 3 Application 4 Installation 5 Operation 10 Service and Maintenance 11 Trouble Shooting 12 Wa...

Страница 3: ...alia Pty Ltd 2017 Model Data Model Motor W AJP60 600 AJP80 1100 MMP1200 1100 Technical Information Inlet Suction 1 BSPF Outlet Discharge 1 BSPF Water Temperature Range 1 40 C IP Rating IPX4 F Electric...

Страница 4: ...s are suitable for pumping clean water in a domestic water system small irrigation applications and as pressure booster pumps The strength of the stainless steel pump casing coupled with the imperviou...

Страница 5: ...nt service work The pump is designed to be used with clean water in a residential application Do not use it with alternative fluids abrasive corrosive or explosive fluids Do not install or operate you...

Страница 6: ...the weight or misalignment We recommend the pump and pipe are coupled using flexible type polythene pipe rubber hose or a multi directional barrel union This union coupling can also be used to remove...

Страница 7: ...the most important part of the installation as errors will cause significant problems for the system in performance and longevity IMPORTANT A gate valve must be installed at the tank outlets Installa...

Страница 8: ...riming Ensure that there is at least 200mm of water in your tank i e that the tank outlet is covered and the pump will not draw any air into the system Open the gate valve on the tank Check for any le...

Страница 9: ...tection This connection shall be separated again only for service purpose and only after the power supply is removed by unplugging the cord from the socket outlet The socket outlet shall be in a dry a...

Страница 10: ...y The priming operation requires a few minutes and it may also be necessary to fill the pump body with water several times accordingly to length and diameter of the suction pipe Note If the pump is no...

Страница 11: ...electrical system and or pump If service is required to the power supply cord and or appliance connectors they must be replaced with the specialised cord assemblies by Pentair Water service agent or s...

Страница 12: ...is not submerged enough Make the suction pipe longer max 8 metres Suction pipe is taking in air Check the suction pipe and joints for air leaks Suction pipe strainer or non return valves are clogged...

Страница 13: ...im the warranty To claim under this warranty the consumer should immediately cease using the goods when an alleged product issue arises For infield service the consumer should promptly notify a Pentai...

Страница 14: ...absolute discretion 12 General Maintenance It is the responsibility of the consumer to ensure the product is free from general debris any foreign matter and weather exposure For general service mainte...

Страница 15: ...15 L100235 Autojet Multimax Owner s manual Copyright Pentair Australia Pty Ltd 2017 Notes...

Страница 16: ...entair Australia Pty Ltd Any reproduction display publication modification or distribution is strictly prohibited without the prior written permission of Pentair Australia Pty Ltd Disclaimer Every end...

Отзывы: