Service and Maintenance
Pump should only be serviced only by qualified personel. For best
results, use only genuine service parts. Be sure to prime pump
before starting.
To avoid dangerous or fatal electrical shock, turn OFF power to pump
and remove plug from outlet before attending the pump.
RCD tripping indicates an electrical problem. If RCD trips and will
not reset have a qualified electrician inspect and repair electrical
system and/or pump.
If service is required to the power supply cord and/or appliance
connectors, they must be replaced with the specialised cord
assemblies by Pentair Water service agent or similarly qualified
personnel in order to avoid a hazard.
Water may be HOT, release pressure with care before servicing.
1. General Care and Maintenance
Under normal conditions the Flotec AJ & MM series of pumps requires only
minimal attention.
In order to prevent possible failures, it is advisable to periodically check the
pressure supplied and power absorption. A decrease in pressure is a symptom
of wear. An increase current absorpion is a sign of abnormal mechanical function
in the pump and/or motor.