BE6000 Ultrasonic Flow Meter O&M Manual
Flomotion Systems, Inc. ~ FlomotionSystems.com
9
6. Technical Specifications
Classification Performance/Parameter
Materials
Steel, Stainless Steel, Cast Iron, Plastics, Concrete,
etc.
Inner Diameter
0.5 to 236 in. (15 ~ 6000mm)
Pipe
Straight Pipe Section
Requirement
10D upstream, 5D downstream (required length may
be longer depending on site conditions)
Types
Clean, sonically conductive
Turbidity
Smaller than 10,000ppm(mg/l) with a low level of air
bubble content
Fluid
Temperature
-4° to 140° F (-20° to 60°)
Flow Velocity
-53 to +53° F (-16 to +16 m/s)
Pipe Size Range
S: 0.5 to 4 in. (15 ~ 100mm)
M: 2 to 40 in. (50 ~ 1000mm)
L: 12 to 236 in. (300 ~ 6000mm)
Transducer
Mounting Method
‘V’ method: Suitable for pipe sizes 16 in. (400mm) or
smaller
‘Z’ method: Suitable for pipe sizes 10 in. (250mm) or
larger
Cable Length
16 ft (5m) Std. (longer lengths available)
Display
Alphanumeric 2 x 20 digit backlight LCD
Keyboard
4 x 4 keypad
Mounting
Wall Mount or optional Panel Mount
Output
4-20mA or 0-20mA analog output, frequency output
(12-9999Hz), relay, serial output.
Power
Wall Mount: 120VAC & 24VDC
Panel Type : 120VAC
Dimension
Wall Mount: 9.9 x 3.6 x 3.2 in. (251 x 92 x 80mm)
Flow Computer
Weight
7 lbs. (3kg) Wall Mount
Temperature
Flow Computer: -4 to 158º F (-20 to 70º C)
Transducer: -4 to 140º F (-20 to 60º C)
Operating
Condition
Humidity
Flow Computer: 85% RH at 104º F (40º C)
Transducer: 98% RH at 104º F (40º C) (Able to
operate immersed in water depth smaller than 3m)
Accuracy
±1.0% of reading above ±1 fps
Repeatability
±0.2% at 1 to 53 fps (0.3 ~ 16m/s)
Performance
Linearity 0.5%
7. Power Connection
Attention
: Meter can be badly damaged if a different power from what was specified is supplied. Careful
attention is advised.
The meter can use standard 120VAC or 24VDC power supply. By default, the meter is provided with the
standard 120VAC power type. Therefore, should the user want 24VDC model, such should be indicated
when ordering.