![Flomotion Systems be6000 series Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/flomotion-systems/be6000-series/be6000-series_installation-and-operation-manual_2306731041.webp)
BE6000 Ultrasonic Flow Meter O&M Manual
Flomotion Systems, Inc. ~ FlomotionSystems.com
41
Appendix 1. RS-232 Command Protocol
COMMAND
PC->METER
DATA RETURNED
METER -> PC
COMMAND
PC -> METER
DATA RETURNED
METER -> PC
DQD(CR)
Flow rate, everyday
M@(CR)
Simulates key pressing on the
instrument.
DQH(CR)
Flow rate, every hour
LCD(CR)
Current LCD display
DQM(CR)
Flow rate, every minute
C1(CR)
OCT combined
DQS(CR)
Flow rate, every second
C0(CR)
OCT separate
DV(CR)
Flow velocity
R1(CR)
RELAY combined
DI+(CR)
Positive total
R0(CR)
RELAY separated
DI-(CR)
Negative total
F0n(CR)
To make frequency output as “n”
value
DIN(CR)
Net flow total
A0a(CR)
To make current loop output as
“a” value
DIE(CR)
Energy total
BA1(CR)
Binary value of A1 input
DL(CR)
Signal strength
BA2(CR)
Binary value of A1 input
DS(CR)
A0 output in percentage
AI1(CR)
Value of A1 input
DC(CR)
Current Error Code
AI2(CR)
Value of A2 input
DA(CR)
OCT or RELAY alarms
ESN
Electronic Serial Number
DT(CR)
Current date and time