![Flomotion Systems be6000 series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/flomotion-systems/be6000-series/be6000-series_installation-and-operation-manual_2306731020.webp)
BE6000 Ultrasonic Flow Meter O&M Manual
Flomotion Systems, Inc. ~ FlomotionSystems.com
20
(2) Initial Setup
•
Pipe Outer Perimeter(M10)
Input the outer perimeter of the pipe. If the outer diameter is available, please ignore this value
and input the outer diameter of the pipe in M11.
•
Pipe Outer Diameter(M11)
Input the outer diameter directly or input the outer perimeter in M10. The value should be between 10mm
and 6,000mm.
Attention: Either outer diameter or outer perimeter is ok.
•
Pipe Wall Thickness(M12)
Input the pipe wall thickness, if available, or skip this and go into M13.
•
Inner Diameter(M13)
Input the inner diameter. If you have input other diameter or outer perimeter and wall thickness, skip this
window.
Either the wall thickness or the inner diameter is ok.
•
Pipe Material(M14)
You can select one of the following materials from the list provided;
0. Carbon Steel
5. PVC
1. Stainless Steel
6. Aluminum
2. Cast Iron
7. Asbestos
3. Ductile Iron
8. Fiber Glass- Epoxy
4.
Copper
9.
Other
Input the Outer Diameter of Pipe
165mm
Pipe Wall Thickness
5mm
Pipe Inner Diameter
155mm
Pipe Material
0. Carbon Steel
Input the Outer Perimeter of Pipe
518.363mm