2.3 Pump Mounting and Collet Installation Procedure
1. To install the pump housing on the gearbox, slide it over the central pilot on the gearbox adaptor plate.
Next install and torque the mounting screws to 5 NT.M (45 in. oz).
2. Next install the collet on the gearbox shaft. There is a slot in the collet that the flat drive tang on the
gearbox shaft must slide into. Orient the collet to allow the drive tang to slide into the slot and push the
collet completely onto the gearbox shaft. When the collet bottoms out it is in the correct position.