![Flomotion Systems 2001H K4 Series Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/flomotion-systems/2001h-k4-series/2001h-k4-series_installation-and-operation-manual_2306735007.webp)
2001H Series Peristaltic Pump O&M Manual
2.1 Tubing, Spindle and Cover Installation
! IMPORTANT: Disconnect pump controller from power supply BEFORE changing tubing!
Item No.
Qty
Part No.
Description
1
1
n/a
Pump Body
2
1
100511
Roller Assembly
3
1
100304B
Cover
4
1
100324
Collet Screw
5
1
100305C
Cover Gasket
6
4
100307C
Cover Screw
7
1
varies
Tubing
8
1
Varies with tubing selection*
Tube Seal
*Tube Seal PN
100329
100330
100331
100332
100333
100334
Flomotion Systems, Inc. 2001H Series
Pg. 7
Tubing is shown bent forward out of the pump
housing to illustrate the correct tubing and roller
assembly position, prior to sliding the tubing and
spindle into the housing and over the collet.