![Flomec Oval Gear Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/flomec/oval-gear/oval-gear_operation-manual_2306721017.webp)
17
Notes for Connection of Reed Only Pulse Output Boards
1.
Reed Only pulse output boards are fitted with an on-board current limiting resistor
which will limit the total power into the circuit to
less than 1W at 24V
(dc) (when using
both outputs). This limitation provides perfect conditions for maximum Reed Switch
service life, and is required for use as a Simple Apparatus within a Hazardous Area.
When used in a Safe Area (non-hazardous) the current limiting resistor can be bypassed
by joining the solder link on the top surface of the PCB, however this will reduce Reed
Switch life.
Please note that it is the responsibility of the user to ensure that total
power remains below 1W when used in a Hazardous Area.
2.
The output resolution from each Reed Switch is as per the calibration sheet delivered
with the flowmeter; wiring the Reed Switch outputs in parallel will double the output
resolution
(015 ~ 100 models only).
2.4.3
Reed Only Outputs as Simple Apparatus
When purchased with a ‘Reed Only” output the meter can be wired as an Intrinsically Safe
Simple Apparatus,
see section 2.7.4 for further explanation of simple apparatus
. The
wiring diagram below shows wiring of the Reed Switch signal from a meter located in the
hazardous area, to an MTL 5532 pulse isolator located in the safe area. The MTL pulse
isolator is shown as it is a common choice; however other brands and models of isolator
may be used in the same way provided they are designed for pulse or frequency signals.
Any barriers/isolators should only be installed after reading the manufacturer’s
instruction manual.