CMS-120
Coolant Management System
40201194
QUICK START
INSTRUCTIONS
Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874
Page
7
of
8
COOLANT FILTER REPLACEMENT
If pressure or a vacuum is shown on either tank gauge,
depressurize the tanks by turning
Tank Control
and
Assist
Control
to
VENT
.
Close the ball valve on the
black
service hose and connect
the open-end adapter.
Turn
Tank Control
and
Vacuum Control
to
GREEN
and
move the
Flow Control
to “
ON
”.
Place the open-end adapter into an approved coolant waste
container and open the ball valve.
NOTE:
The reservoir will not completely empty and will only
empty past the threads, so the reservoir may be removed
without spillage.
Once at this level, move the
Flow Control
to “
OFF
”, turn
Tank Control
to
VENT
, and
Vacuum Control
to
OFF
.
Remove the reservoir by turning it counterclockwise. Empty
the reservoir contents into an approved coolant waste
container, rinse out the reservoir, and replace the filter if
necessary.
After ensuring the rubber O-ring is in place, reinstall the