CMS-120
Coolant Management System
40201194
QUICK START
INSTRUCTIONS
Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874
Page
4
of
8
ADDITIONAL FUNCTIONS
COOLING SYSTEM PRESSURE / LEAK CHECK
Move the
Flow Control
to “
OFF
” and connect shop air to
the machine.
Close the ball valve on the
red
service hose. Connect the
red
service hose to the top of the radiator using the
appropriate adapter and open the ball valve.
Turn
Tank Control
and
Assist
Control
to
YELLOW
position.
Move the
Flow Control
to “
ON
”.
The system will pressurize to 10-15psi.
Turn
Tank Control
to
RED
and observe the
Fluid Tank
pressure gauge. If there is a loss of pressure, then there is
a leak in the cooling system.
When enough time has elapsed to properly perform a
pressure check, move the
Flow Control
to “
OFF
” and
Tank
Control
and
Asist Control
to
VENT
.
Close the ball valve on the
red
service hose and remove
the
red
service hose. Remove the adapter from the radiator
and replace the cap.