DRAINING THE TANK
Close the ball valve on the
black
service hose and connect
the open-end adapter.
Turn
Tank Control
and
Assist Control
to
GREEN.
Move the
Flow Control
to “
ON
”
Place the open-end adapter into an approved coolant waste
container and open the ball valve. Drain until the tank is
empty.
Move the
Flow Control
to “
OFF
” and
Tank Control
and
Assist Control
to
VENT
to release pressure in the tank.
Dispose of used coolant in accordance with local and state
requirements.
EMPTY OVERFLOW BOTTLE
Release the Velcro strap and remove the overflow bottle.
Empty contents into an approved coolant waste container.
Rinse out and replace using Velcro strap.
VACUUM GENERATOR OVERFLOW FILTER REPLACEMENT
The vacuum generator overflow filter should be emptied
when it is more than 1/3 full.
Remove the reservoir by turning it counterclockwise. Empty
the reservoir contents into an approved coolant waste
container, rinse out the reservoir, and replace the filter if
necessary.
After ensuring the rubber O-ring is in place, reinstall the