![FLO-DYNAMICS CMS-120 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/flo-dynamics/cms-120/cms-120_quick-start-instructions_2306471002.webp)
CMS-120
Coolant Management System
40201194
QUICK START
INSTRUCTIONS
Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874
Page
2
of
8
When air is seen in the
black
hose, turn
Tank Control
and
Assist Control
to
VENT
and
Vacuum Control
to
OFF
.
When air pockets/coolant stop moving in the service hoses,
move the
Flow Control
to
“OFF”
.
Close the ball valves and remove the service hoses.
PERFORM COOLANT FILL OPERATION
RETURN COOLANT TO VEHICLE AFTER SERVICING
Move the
Flow Control
to “
OFF
” and connect shop air.
Connect the
red
service hose to highest point, the
black
service hose to the lowest point, and open the ball valves.
Turn
all
control panel dials to the
GREEN
position.
Move the
Flow Control
to “
ON
”.
The system will begin to fill.
When the coolant level is at the “cold” level of the
expansion tank or seen in the
red
hose, the system is full.
Turn
Tank Control
to
VENT
and
Vacuum Control
to
OFF
.
The coolant level will adjust.