SPECIFICATION

Specifications are subject to change without notice.

Electrical Specifications

Output Functions

The Tracer 1000 is an active, single 

ended, non-isolated, 3 or 4 wire analog 

output transmitter.

Analog Output 

(Active)

Current output 4-20mA: The span 

between the lower range value [4mA] 

and the upper range value [20mA] 

is equal to 0-100% of the continuous 

level measurement reading as a factory 

default.  Output can be inverted.

Total Load 

Resistance

< 500Ω: HART resistor approx. 250Ω 

+ load resistance approx. 250Ω if the 

current output is connected to a device 

with an inner resistance of approx. 250

then there is no additional external HART 

resistor necessary. In that case, the 

HART modem is connected in parallel to 

the current output wires.

Lower Range Value

4.0mA (span 0%)

Upper Range Span

20.0mA (span 100%)

Response Time

0.5s (default), 2s 5s (selectable)

Temperature Drift

Less than .0078 in/ºF change in ambient 

temperature

Switch Output

DC Switch, PNP, Active, Max. Load 200 

mA Current.

Supply Voltage

12-30VDC (reverse-polarity protected)

Current 

Consumption

< 50mA at 24 VDC (no burden)

Start-Up Time

< 6s

Cable Terminals

Screwless, cage clamp terminal block for 

stranded and solid wires AWG 22-14.

Measurement Specifications

Accuracy

± 0.12” or 0.03% of measured distance, 

whichever is greatest

Repeatability

< .08”

Resolution

< .04”

Probe Type

316 SS Rod: 1/4” Dia. (Coated Rod; 3/8” Dia.)

316 SS Coaxial: 3/8” Dia. 

Wire Cable: 1/2” Dia.

Probe Length [L]

316 SS Rod: 2.41” - 120”

316 SS Coaxial: 0” - 120”

Wire Cable: 2.41” - 480”

(Length must be specified when ordering - The reference point 

is always the sealing surface of the connection thread - See 

dimensional drawings)

Top Dead Band

0” Coaxial Probe

2.41” Rod or Wire Probe

Measuring Range 

[M]

Up to 780” depending on probe type

Switching Point [S]

Freely positionable within the measuring 

range [M] Hysteresis can be set by 

defining seperate upper and lower 

thresholds; if those are set at the same 

position, the minimum hysteresis of .11” 

applies

Application Specifications

Dielectric Constant 

r

]

Wire & Cable Probe: Configurable

Coaxial Probe: 0

Conductivity

No restrictions

Density

No restrictions

Standard 

Application Temp.

F: -40º to 410º

C: -40 to 150º

Optional 

Application Temp.

F: -320º to 500º

C: -195 to 260º

Ambient 

Temperature

F: -13º to 176º 

C: -25º to 80º

Application 

Pressure

-14.50 PSI to 580 PSI

Velocity of Level 

Change

< 3.2 fps

Mechanical Specifications

Wetted Materials

1.4404 / 316L and PEEK, PTFE

Enclosure Material

Aluminum alloy EN AC-AISi9Cu3 (DIN EN 

1706), Epoxy Spray (~70µm)

Enclosure Rating

Standard: NEMA 6 (IP68)

Explosion Proof Option: ATEX NEMA 7

Cable Glands/Screw 

Plugs

1/2” NPT (2) or

Cable Glands (2) or

1/2” NPT (1) & Cable Gland (1) or

M20 x 1.5 (2) or

M20 X 1.5 (1) & Cable Gland (1)

Connection Thread

3/4” NPT (US) or 3/4” G (Metric)

Weight (Less Probe)

1.99 lbs. (903.8 g)

Certification

FM:  Class I Groups A,B,C,D

Class II Groups E,F,G; Class III; Type 4X

Class I, Div. I, AEx D IIC; IP66

Class I, Div. I, Ex d II C

Содержание TRACER 1000 LTT1

Страница 1: ...877 356 5463 p 330 331 7331 f 330 331 7172 www FLO CORP com 2017 FLO CORP REVA 1116 1 TRACER 1000 LTT1 GUIDED WAVE RADAR LEVEL TRANSMITTER OPERATING INSTRUCTIONS...

Страница 2: ...zed Personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorized by the plant operator During work on and with the devic...

Страница 3: ...8 Resolution 04 Probe Type 316 SS Rod 1 4 Dia Coated Rod 3 8 Dia 316 SS Coaxial 3 8 Dia Wire Cable 1 2 Dia Probe Length L 316 SS Rod 2 41 120 316 SS Coaxial 0 120 Wire Cable 2 41 480 Length must be sp...

Страница 4: ...wells Bypass chambers and stilling wells Limited headroom for installation Limited headroom for installation Tall tanks Tall tanks MEDIA CHARACTERISTICS MEDIA CHARACTERISTICS Bulk solids Bulk solids...

Страница 5: ...80 PSIG Preparation FLO CORP s Tracer 1000 level transmitters are ready to install as is and are completely pre configured per the application data sheet or customer application information at time of...

Страница 6: ...is made of 316L Stainless Steel 1 4 diameter The Rod probe can be ordered with an optional teflon isolation sleeve and connections Both configurations have a threaded female connection on one end and...

Страница 7: ...und it will be connected to is exactly equal to the ground potential of the transmitters power If there is a ground offset you will potentially experience faulty signal outputs The grounding screw is...

Страница 8: ...877 356 5463 p 330 331 7331 f 330 331 7172 www FLO CORP com 2017 FLO CORP REVA 1116 8 Figure 3 Wiring Diagram Interconnecting Wiring to DigaCom 2000 Typical 3 Wire Connection...

Страница 9: ...877 356 5463 p 330 331 7331 f 330 331 7172 www FLO CORP com 2017 FLO CORP REVA 1116 9 External Power Wiring To Input ie PLC External Powered Wiring To DigaCom 2000 Level Monitor...

Страница 10: ...877 356 5463 p 330 331 7331 f 330 331 7172 www FLO CORP com 2017 FLO CORP REVA 1116 10 PNP Output Wiring...

Страница 11: ...ONLY BLUE Indicates the DIP switch positions through which groups of functions are selected example all functions related to the analog current output or the switching output GRAY Indicates the DIP sw...

Страница 12: ...w seconds while the disturbance signal scan is being performed Once the scan is completed successfully the LED will return to blinking alternately green and red If this is the only function you want t...

Страница 13: ...the tank to the level of the tank where you want the switch point to be activated Next set the following DIP switch to the ON 1 position 8 6 3 All other switches should be in the off position The LED...

Страница 14: ...surface of the connection thread The probe length is an important mechanical dimension which is needed to make sure the probe physically fits into the tank at the anticipated mounting location The pr...

Страница 15: ...by returning to the RUN mode Tracer still reading high Increase upper deadband to medium 7 4 This may require adjustment of 20mA set point 1 2 Tracer 1000 erratic output throughout the span of the pro...

Страница 16: ...by returning to the RUN mode Tracer still reading high Increase upper deadband to medium 7 4 This may require adjustment of 20mA set point 5 2 Tracer 1000 erratic output throughout the span of the pro...

Страница 17: ...h button Verify output by returning to the RUN mode Tracer still reading high Increase upper deadband to medium 7 4 This may require adjustment of 20mA set point 9 2 Tracer 1000 erratic output through...

Страница 18: ...struct your FLO CORP Model Number Simply match the category number to the corresponding box number Example LTT1 RN6 01 120 N 000 Tracer 1000 GWR Level Transmitter with 316 SS Rod Probe Type NEMA 6 Enc...

Отзывы: